My WebLink
|
Help
|
About
|
Sign Out
Home
pf_03315
Roseville
>
Planning Files
>
Old Numbering System (pre-2007)
>
PF3000 - PF3801
>
3300
>
pf_03315
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/26/2007 12:15:24 PM
Creation date
12/9/2004 7:24:20 AM
Metadata
Fields
Template:
Planning Files
Planning Files - Planning File #
3315
Planning Files - Type
Conditional Use Permit
Address
803 LARPENTEUR AVE W
Applicant
Roselawn Cemetery
Status
Denied
Date Final City Council Action
8/27/2001
Planning Files - Resolution #
9927
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
318
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />Emissions Testing Results <br /> <br />Page 1 of 3 <br /> <br /> <br />Home <br /> <br />About CANA <br /> <br />Membership <br /> <br /> <br />Testing Results: <br /> <br />Visible Emissions: <br />The visible emissions were evaluated every 15 seconds and <br />rated on a scale from 0% to 100% opacity by a qualified <br />inspector. <br /> <br />Cremationist <br /> <br />The opacity readings for each cremation were then averaged <br />over the six-minute period with the highest emissions. Figure <br />1 shows that visible emissions increased as the operating <br />temperature increased. Comparison is given to a typical state <br />emission limit. <br /> <br />Statistics <br />EnvironmentaJ <br /> <br />Li n ks <br /> <br />HistolY <br /> <br />Particulate Matter: <br />The results of sampling show that particulate matter emissions <br />also increased with temperature. Overall, the emissions of <br />particulate matter were very low. <br /> <br />Burial At Sea <br /> <br />The average test results for particulate matter (shown in Figure 2) as well as the <br />results for all of the following pollutants, are for the inlet to the scrubber. A <br />comparison of the emissions before and after the water scrubber showed that the <br />device had little to no effect on the emissions of any of the pollutants. <br /> <br />Carbon Monoxide: <br />The levels of carbon monoxide (flgure 3) were very low for each test condition, <br />well below the typical state standard of 100 parts per million. <br /> <br />Nitrogen Oxides and Sulfur Dioxide <br />The levels of these gases (shown in Figures 4 and 5) were within acceptable <br />limits. <br /> <br />Hydrogen Chloride: <br />Hydrogen chloride (HCI) is a gaseous pollutant produced by the burning of <br />plastics or other material containing chlorine. The HCI emissions would not be <br />expected to change with temperature. The average HCI emission for all the <br />conditions was 0.15 pound per hour of operation. <br /> <br />Metals: <br />Like HCI, emissions of mercury, cadmium, and lead are not expected to vary with <br />operating temperature. The metal of concern from crematories is mercury, which <br /> <br />http://www .cremationassociation.org/html/tescresults.html <br /> <br />06/20/2001 <br />
The URL can be used to link to this page
Your browser does not support the video tag.