My WebLink
|
Help
|
About
|
Sign Out
Home
pf_03338
Roseville
>
Planning Files
>
Old Numbering System (pre-2007)
>
PF3000 - PF3801
>
3300
>
pf_03338
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2007 1:29:43 PM
Creation date
12/9/2004 7:26:11 AM
Metadata
Fields
Template:
Planning Files
Planning Files - Planning File #
3338
Planning Files - Type
Planned Unit Development
Address
3015 CENTRE POINTE DR
Applicant
CENTRE POINTE/SOLUTIA
Status
Approved
PIN
052923110037
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
466
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />Centre Pointe Site ..Intersection of County Road C and Cleveland <br />P d' d M' CO I <br /> <br /> re Icte aXlmum mpacts <br />Receptor Projected CO 1 Hour Average 8 Hour Average <br /> Concentration CO from Source CO from Source <br /> From Source Intersection Plus Intersection Plus <br /> Intersection Background" Backgroundb <br /> (ppm) (ppm) (ppm) <br />1 (Proposed Office) 0,0 3.6 2.6 <br />2 (Proposed Office) 0.0 3.6 2.6 <br />3 (Hotel) 0,0 3.6 2.6 <br />4 (Office) 0.0 3.6 2.6 <br />5 (Residential) 0.0 3.6 2.6 <br />6 (Residential) 0.0 3.6 2,6 <br />7 (Office/WH) 0.1 3.7 2.7 <br /> <br />Centre Pointe Site -Intersection of County Road D and Cleveland <br />P d' d M' CO I <br /> <br /> re Icte aXlmum m pacts <br />Receptor Projected CO I Hour Average 8 Hour Average <br /> Concentration CO from Source CO from Source <br /> From Source Intersection Plus Intersection Plus <br /> Intersection Background" Backgroundb <br /> (ppm) (ppm) (ppm) <br />1 (Proposed Office) 0.2 3,8 2.8 <br />2 (Proposed Office) 0.1 3.7 2.7 <br />3 (Hotel) 0.1 3.7 2.7 <br />4 (Office) 0.2 3.8 2.8 <br />5 (Residential) 2.1 5.7 4.7 <br />6 (Residential) 2.0 5.6 4.6 <br />7(Office/WH) 0.2 3.8 2.8 <br /> <br />aCity of Roseville, 1 Hour Adjusted Average = 3.6 ppm. <br />bCity of Roseville, 8 Hour Adjusted Average = 2.6 ppm. <br /> <br />CO levels predicted at each receptor by modeling traffic levels at County Road C are very <br />low. This is because, although it is the busiest intersection by traffic count, the intersection <br />of Cleveland and County Road C is relatively far from the receptor locations established. <br /> <br />It can be seen from the above table that the CO standards are not projected to be exceeded at <br />any of the receptor locations assuming the project is developed as envisioned, and using the <br />information and methods outlined above, With the increase in traffic caused by the <br />additional 15,500 SF of office it is unlikely that the Co standards will be exceeded. Thus, it <br />is not anticipated that traffic improvements or other mitigation measures will be required to <br />address air quality issues associated with the proposed project. <br /> <br />Environmental Assessment Worksheet <br />Centre Pointe Business Park <br /> <br />Page 22 of 29 <br />
The URL can be used to link to this page
Your browser does not support the video tag.