My WebLink
|
Help
|
About
|
Sign Out
Home
pf_01977
Roseville
>
Planning Files
>
Old Numbering System (pre-2007)
>
PF1000 - PF1999
>
1900-1999
>
pf_01977
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2007 1:33:24 PM
Creation date
12/9/2004 3:05:53 PM
Metadata
Fields
Template:
Planning Files
Planning Files - Planning File #
1977
Planning Files - Type
Variance
Address
3003 SNELLING AVE N
Applicant
NORTHWESTERN COLLEGE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
94
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br /> <br />4. Peak flows will most likely not be simultaneous. Paul'!' <br />Place, the Northwestern Col lege residence hal Is and the <br />proposed Ufe and Health Fitness Center, wlJ I uti I Ize the. <br />sanl tary sewer facilities at different times. Since the <br />residents of the CoI lege are al so gal ng to be utlllz Ing <br />the Life and Health Fitness Center, peak flows fran the <br />campus wll I not be concurrent. <br /> <br />See Appe nd I x for more detail ed cal cui atl ons. The 11ft station <br />appears to be able to handle even total peak flows and should <br />easll y handl e average da II y flows. <br /> <br />B. <br /> <br />W~j~r_~.!.!J2~l~_.aDsj_Dl~trl.bJ.ltl.oD_til.cllijl~~ <br /> <br />A new 8-1 nch watermal n I s proposed to be extended to the Life <br />and Health Fitness Center at the same time as the proposed <br />sanitary sewer, as shown on Exhibit G. Hydrants are proposed to <br />be spaced at a 500 foot maximum radius around the Fitness <br />Center. Yard hydrants will be no closer than 50 feet fran the <br />bul I dl ng. <br /> <br />The existing 6-lnch watermaln serving the residence halls Is <br />proposed to serve the future resl dence hal I to th e east of the <br />ex I st I ng resl dence hal I s. The current pressure and size of the <br />exl stl ng watermal n are such that al I recommended pressures for <br />future sprinkling and fire protection of the proposed residence <br />hal I may require reinforcement. To provide additional capacity, <br />the proposed 8-1 nch I I ne w I I I be extended to the east sl de of <br />the Life and Health Fitness Center to al low for possible <br />extension to the new residence hal I, should facilities require <br />It. <br /> <br />-16- <br /> <br />8621 <br />
The URL can be used to link to this page
Your browser does not support the video tag.