Laserfiche WebLink
ATTACHMENT B <br />Attachrr�ent � <br />-over- <br />Inspection Report <br />The inspection revealed: <br />Evidence of rodent harborage — Storage closet main floor <br />Door locks at entry not functional <br />Window covering in disrepair — numerous around building <br />Common area outlets are painted over <br />Dryer exhaust not connected — venting into room <br />Dryer exhaust ducting has screws penetrating duct <br />Exhaust vent for stove has unlisted covering/paint — Unit 21, 9 <br />Kitchen cabinet in disrepair — Unit 9 <br />Bed in living room *smoke co detector rules apply if allowed to be sleeping room — Unit 24 <br />Bedroom door knob in disrepair — Unit 24 <br />Carbon Monoxide detector required within 10 feet of sleeping room — Unit 10,3,4 *please verify in all units <br />Paint Peeling in dining room — Unit 9 <br />Missing smoke detectors inside sleeping rooms <br />Flexible drain connector under bathroom sink — Unit 3,9 <br />Kitchen sink drain leaking — Unit 4 <br />Check valve and rubber drain connection under kitchen sink — Unit 4 <br />Bathroom door lock/latch not functioning — Unit 10 <br />Outlet painted over — Unit 13, 3— Living room, Unit 10 — Kitchen, Unit 3- Bedroom <br />Broken outlet in bedroom — unit 13 <br />Exterior building lighting not operable <br />Bare ground in excess of 20 square feet <br />Dumpster enclosure is in disrepair, Dumpster must remain behind screen (out of view from public right of <br />way) <br />Junk and debris on grounds/outside of dumpster enclosure Any and all deteriorated trim(failing paint, <br />rotting material, broken mouldings) needs replacement around garages and garage doors(any/all cladding <br />within 6" of grade is required to be treated or other weather resistant material) <br />Horizontal joints in siding and/or trim require drip caps <br />Siding sections with over 10% peeling/fading/deteriorated paint needs to be re-painted in its entirety <br />Garage doar panels having holes, dents, deteriorated paint ar significant damage in excess of 25% (of each <br />individual panel) needs replacement <br />All misaligned garage doors need re-alignment in their openings <br />These conditions are violations of Roseville's City Code, specifically: <br />Section 906 which requires Exterior/lnterior/Site shall be inaintained in good repair <br />Section 906.09 which requires Smoke Detectors in each sleeping room <br />Minnesota State Statute 299F.51 which requires Carbon Monoxide detectors within 10 feet of each <br />sleeping room <br />The City is requesting that steps be taken to: <br />Repair noted items <br />Install smoke detectors inside each sleeping room <br />Install Carbon Monoxide detectors within 10 feet of sleeping rooms <br />Timeframe for Compliance: <br />5 days for: Smoke/Carbon Monoxide Detector Installation � <br />30 days for: Maintenance/Repair of noted iteins* <br />*lf the timeline for this request creates a hardship for you or if you have any questions or concerns regarding this <br />notice or licensing requirements, please contact me at 651-792-'7013. <br />Again, thank you for your attention and cooperation with Roseville's Rental License Program. <br />Dave Englund, Code Enforcement Officer Ciry of Roseville dave.en lu�nd(a�ci.roseville.mn.us <br />