Laserfiche WebLink
Solution( <br />Blue <br />November 26, 2014 <br />Steve Zawadski <br />Zawadski Homes <br />4614 Churchill Street <br />Shoreview, MN 55126 <br />Solution Blue, Inc. <br />318 Cedar Street <br />Saint Paul. MN 55101 <br />Attachment D <br />Phone: 651-294-0038 <br />Fax: 651-395-3326 <br />www.SolutionBlue.com <br />Re: Permeable Interlocking Concrete Paver Driveway located at 365 South Owasso Blvd. Roseville, Minnesota. <br />Dear Mr. Zawadski - <br />Per your request, we are preparing the design plans for a permeable interlocking concrete paver driveway for your project at <br />365 South Owasso Blvd. Roseville, Minnesota. Our services include work to be completed by a Professional Civil Engineer <br />(PE), Certified Storm Water Pollution Prevention Plan (SWPPP) Designer, and other Solution Blue Team members. The <br />following "Supporting Exhibits" and Work scope outlines our project scope. <br />Assumotions and/or Understandina of the Proiect: <br />- Site is located in the City of Roseville ("City") and within Ramsey County ("County"). <br />- Site contains one (1) existing parcel that is 12,908 square feet in size - per survey prepared by E.G. Rud & Sons Inc. <br />- The private owner ("Owner") is planning to build a residence with covered porch and stoop totaling 2,262 square foot <br />(SF) on foundation. In addition, entry walk of 21 SF and Patio 311 SF. The proposed permeable interlocking concrete <br />paver driveway is 1,266 SF. It is understood that by proving a permeable interlocking concrete pavers driveway you will <br />be able to reduce the proposed impervious surface area impervious calculated by 50% (633 SF). Therefore, the total <br />proposed impervious area is 3,227 SF and is 25% of parcel. <br />- Zawadski Homes ("Zawadski") is leading the planning, design, regulatory approvals and construction processes for this <br />project, while working closely with Owner throughout the project. <br />- Zawadski provided Solution Blue, Inc. ("SBI") with a conceptual Site Plan to assist SBI in creating our design plans. <br />- Zawadski and Owner will provide SBI with all available architectural plans (DWG files), site survey (DWG file) property <br />info, soils reports and other related plans/info prior to starting with design. <br />Su000rtina Exhibits: <br />Typical section design detail <br />Typical Permeable Interlocking Concrete Paver Specification <br />Deliverables: <br />Upon City approval of the impervious surface area credit for permeable interlocking concrete pavers. SBI will produce <br />construction documents and final specifications. A soils report will be required to verify that the underlying soils will <br />adequately promote infiltration. <br />If you have any questions or feedback, please contact us at your convenience. We look forward to this opportunity to work <br />together again! <br />Sincerely, <br />John Hink <br />President <br />Page 1 of 7 <br />