My WebLink
|
Help
|
About
|
Sign Out
Home
2015_0112_CCpacket
Roseville
>
City Council
>
City Council Meeting Packets
>
2015
>
2015_0112_CCpacket
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/17/2015 12:12:26 PM
Creation date
8/14/2015 3:43:44 PM
Metadata
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
205
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
This road is located within the Capital Region Watershed District (CRWD). CRWD requires that <br />this project provide volume control and treatment for the storm water runoff. This can be <br />accomplished through a variety of potential Best Management Practices (BMPs) for stormwater <br />management. <br />City staff is recommending the installation of several hundred feet of perforated pipe along the <br />east-west portion of Victoria Street that will allow rate control, provide some infiltration and also <br />address some drainage concerns in the area. The outlet to this new system is proposed to drain <br />into the very southeast corner of Pioneer Park. A pretreatment cell will be installed at this outlet <br />to provide treatment of the stormwater before discharging into the existing wetland in this area. <br />A raingarden is also proposed in the northwest corner of Larpenteur Ave and Victoria St to <br />provide infiltration, rate control and treatment of stormwater before draining into the <br />Larpenteur Ave stormwater system. <br />Erosion Control <br />As part of the project plans and specifications, staff is required to prepare a storm water <br />pollution prevention plan (SWPPP) for the purposes of enforcing erosion and sediment control <br />rules. The SWPPP will include erosion and sediment control methods that will be implemented <br />throughout the project. Silt fence, bio-rolls, erosion control blanket, and other best <br />management practices will be utilized where direct runoff might occur. Inlet protection will be <br />used to protect both the existing and new catch basins during construction. Street sweeping will <br />occur, as needed, on all paved street surfaces throughout the project, including intersecting <br />streets. Exposed soils and aggregate material will be watered as needed as a dust-control <br />measure. An erosion and sediment control plan sheet and storm water pollution prevention <br />plan will be created during the design phase of this project. Immediate turf establishment in <br />areas of soil disturbance will be required such as placing seed and erosion control blanket. After <br />street and utility work is completed, sod and/or hydro mulched seed will be placed as the <br />permanent turf establishment in all disturbed areas. The City, in coordination with the <br />watershed district, will closely monitor all erosion and sediment control measures throughout <br />the construction process. The selected contractor will be required to install all preventative <br />measures and maintain them as required by the City, CRWD, MPCA, and other regulatory <br />agencies. <br />C. Private Utilities <br />Private utility companies have been notified that this project is being considered for construction <br />in 2015. It is their responsibility to relocate facilities within the right-of-way that interfere with <br />the City's proposed project. <br />D. Driveways <br />As a part of our plan preparation, staff reviewed the size, location and material of all existing <br />driveways in an effort to bring them into conformance with City Code at the time of <br />reconstruction. Staff will work with residents to provide a final design that minimizes any <br />additional impact to existing driveways and minimizes stormwater runoff that traverses down <br />the driveways from the roadway. <br />Project P-ST-SW-15-02 <br />Victoria Street Reconstruction <br />24 <br />Feasibility Report <br />
The URL can be used to link to this page
Your browser does not support the video tag.