Laserfiche WebLink
E <br />� <br />m <br />V <br />O <br />N <br />�1 <br />� <br />> <br />O <br />z 5s. <br />O <br />c <br />� <br />� <br />9 <br />� <br />N <br />� <br />� <br />� <br />6� <br />3 <br />� <br />O <br />O <br />� <br />U <br />� <br />� <br />N <br />V <br />N <br />> <br />� <br />U <br />O <br />� <br />5 <br />� <br />� <br />� <br />� <br />O <br />Z <br />� <br />> <br />� <br />� <br />� <br />N <br />� <br />E <br />O <br />L <br />� <br />� <br />N <br />� <br />N <br />� <br />� <br />N <br />V <br />N <br />WATER DISTRIBUTION NOTES <br />I. ALL ELEVATIONS ARE 6ASED ON MEAN SEA LEVEL DATUM. 6. ALL COMPONENTS OF TF1E WATER SYSTEM, UP TO TF1E <br />2. TF1E CONTRACTOR IS RESPONSBLE FOR VEIZIFYING TY1E WATER MCfER OIZ FIRE SERVICE EQUIPMENT 511ALL UTILIZE <br />EXACT LOCATIONS AND ELEVATIONS OF ALL EXISTING PROTECTIVE WTERNAL COATINGS MEETING CURRENT <br />UTILITIrS PRIORTO BEGINNING CONSfRUCTION, IF ANSI/AWWA STANDARDS FOR CEMENi MORTAR LINING OR <br />CONDITIONS ARE SIGNIFICANTLY DIFFERENT FROM TF1AT SPEQAL COATINGS. TF1E USE OP UNLWED OR UNCOATED <br />SI10WN ON TF1E PLANS, STOP WORK AND NOTIPI' TI1E (CAST-IRON, GRAY-IRON, STEEL, GALVANIZED, ETC.) PIPE <br />EN6WEER. SFIALL NOT BE ALLOWED. <br />3. CONTRACTOR SFIALL FIELD ADJUST FIRE FIYDRANTS, VALVES 7. COMBINATION FIRE AND DOMESTIC SERVICES MUST <br />AND APPURTENANCES TO MATCt1 FIN1511ED GROUND TERMINATE WITF1 A TYIREAD ON FLANGE OR AN MJ TO FLANGE <br />ELEVATION. ADAPTER. <br />4. 8 MIL MIN. POLYWRAP ON ALL D.I.P. IS REQUIRED 8. UTILITY AND MEGFiANIGAL CONTRACTORS SF1AI_L <br />5. TAPS OF LIVE WATER MAINS TO 6E DONE BY CITY FORCES. COORDINATE INSTALLATION OF WATER SERVICE PIPES, <br />BUT COORDINATED AND PAID FOP. BY CONTRACTOR FITTINGS, AND VALVES ALL TI1E WAY INTO Tt1E BUILDING TO <br />ACCOMMODATE QN INSPECTION AND TESTIN6. <br />I I <br />� � WATERMAIN CONNECTION 511ALL <br />SAMTARY SEWER NOTES <br />I. ALL ELEVATIONS ARE BASED ON MEAN SEA 4. ALL WATER AND SEWFR LINFS MUST I1AVE <br />EVEL DATUM. A MINIMUM OF I 0 FEET I10RIZONTA <br />L L <br />2. TF1E CONTRACTOR IS RESPONSBLE FOR SEPARATION AND I 8 MCFIES VERTICAL <br />VERIFYING TF1E EXACT LOCATIONS AND SEPARATION. <br />ELEVATIONS OF ALL EXISTING UTILITIES 5. ALL SEWER SERVICES SFIALL BE 6 INCFIES <br />PRIOR TO BEGINNING CONSTRUCTION. IF IN DIAMETER UNLESS OTt1ERWISE NOTED. <br />CONDITIONS AIZE S16NIFICANTLY DIFFERENT 6. CONTIZACTOIZ TO COOIZDINATE <br />FROM TF1AT SF10WN ON TF1E PLANS, STOP CONNECTION TO EXISTING SANITARY <br />WORKAND NOTIFYTFIE ENGINEER. SEWERSYSTEM. <br />3. CONTIZACTOR 511ALL FIELD ADJUST 7. UTILITY AND MECFIANICAL CONTRACTORS <br />MANYIOLE RIMS, QEANOUTS, AND 51-IALL COORDINATE WSTALLATION OF <br />APPURTENANCES TO MATCYi FINISFIED SEWER SERVICES ALL TFiE WAY INTO TF1E <br />GROUND ELEVATION. BUILDING TO ACCOMMODATE QTY <br />INSPECTION AND TESTING. <br />BE WET-TAPPED.CONTPACTOR PROPOSED DOGhOU5E5ANITARY <br />� 511ALL COORDINATE WITI1 QTY SEWER MANY101_E TO INTERCEPT <br />OF ROSEVILLE Ul ILITY DEPARTMENL EXISTING SANITARY MAIN. CONTP.HCTOR <br />`vu s D � TO LOCATE LWE. VF�IFY INVERTS AND <br />o .,,, � � 7�,1s CORRIDNATE CONNECTION WITF1 QiY OF ROSEVILLE. <br />,: � �. ,... . ��. <br />.� c \ j _ _ _ _ . .. <br />j5 9 � _ <br />� "� � o %�Wis wls � is - SNie Vvis — 'w_� 5nis - <br />� w�s �o <br />o ' � <br />� EXISTING 36" RCP SANIT RY SEWEP. ' <br />55,��55, 55.� 55, 55, 55, Ss. 55, 5.� 55. SS, 55,. <br />i� <br />��� � cv z' mv �,�FXISTING I 2 DIP W(jTE -MAII� � `v <br />s 's w. —w, 'Kv�-w.. w m, ',v, d✓, p.�. mi.��.^✓.- <br />0 <br />� <br />N � <br />0 <br />i <br />i �� , <br />�ASEMEN F PU G wAY (DO . N. 4t . <br />- Z <br />% y . —�.... .....___ � - <br />J L_ _ U1 <br />0 JO <br />MIN <br />5 �� f 48 LF 6" PVG WATER 58 LFiB �PVC SANITAKY SEWER <br />SERVICE CONNECTION SEI�VICE CONNEGTION <br />� PROPOSEDFiAMPTONINN — <br />� FFE = 9 I 2.75 � <br />I � <br />9;� <br />910 <br />� � � <br />� K� ' ����� . <br />I � �� <br />� � � � � <br />� I <br />I❑ ❑ <br />� � <br />� <br />I I I I I � <br />— n <br />IONA LANE <br />GENERAL NOTES <br />A) CONTRACTOR SIIALL COORDINATE Tf1E LOCATION OF EXISTING UTLITIES <br />WITFIIN l Y1E CONST�UCTION AREA PRIO� TO TY1E BEGINNING OF ANY <br />EXCAVATION OR DRILLING WORK. CONTRACTOR SFIALL ADJUST, <br />PROTECT AND REPAIR ANY DAMAGE TO SAID UTILITIES, AS NECESSARY, <br />AT NO ADDITIONAL COST TO TF1E OWNER. <br />m <br />1Nis — — — — <br />�N <br />\ <br />� EXISTING 4-STORY MTC � <br />PARKING RAMP � <br />� <br />L� <br />� � �/ <br />i <br />I� <br />z I <br />1 � <br />} <br />w J <br />� nw. <br />3? z <br />5 Q <br />Id N <br />o I � �� <br />—1N1S 'bViS —� N <br />— — — _ _ � � <br />�o z <br />� <br />84 LF S" PVC WATER - x � <br />SERVICE CONNECTION � >' <br />� Wi000� W <br />MiN. _ <br />, 5AN S N <br />N <br />74 LF 8" PVG SAI�,ITARYSEWER <br />SERVICE CONNEGTION Q <br />� i I � O <br />3 <br />� � � <br />�°6� � � PROPOSED h10ME2 SUITES �0 <br />� �o� � FFe = 9 i 6.00 � � �` � <br />� G � <br />z <br />� 0 0 <br />� <br />� II:� � � <br />< <br />� 3 _ � <br />-.� <br />0 <br />/ � � - �z <br />, <br />� � � m � <br />� <br />' / `�— � � ��� � � <br />� � m � — __ _� � � � <br />_ — - w <br />� <br />— w <br />�w � � <br />� � � � 3 � .;:. <br />�i: �\\\ � � . � �p ,x �I <br />i A s <br />�_—_ <br />� in <br />� <br />STM ia�ST —SIM—�iM_—� � S�vl � � 3 <br />� <br />-'' ___-__ � <br />. . , . --:_ ..�_-.-. .. _�. � . . .. . . . . . . - . 3 '^ <br />_. <br />� � � � � <br />�� <br />� ow <br />Exhibit A <br />� � <br />CITIFS E AR -HITE -.T <br />/ , <br />G C C S <br />NORTFI 103 Fikeenth Ave NW, Willlmar, MN 56201 <br />Phone:320-235-7775 Fax:320-235-8673 <br />www. Cities Ed geA rchitects.com <br />LiPE6E0GE LLCASAY.MOLbWME0SV8SONRvOiPPMABERBAHSCLipiE6iN� <br />WATERMAIN CONNECTION Si1ALL <br />BE WET-TAPPED.CONTRACTOR <br />511ALL COORDINATE WITYi CIN <br />OF ROSEVIIIE UTIUN DEPARTMENT. <br />SEE DETAIL ON St1EET C6XX <br />FOR GONNECTION INFOPJVIAiION <br />LEGEND <br />W- <br />SAN <br />s.Nt <br />G. <br />—T,- <br />55, <br />w.- <br />FX Sl ING �VIq,iOK <br />COVTOUKS <br />EXISTING MINOR <br />CONTOURS <br />PKOPOSED MAJOR <br />CONTOURS <br />PROPOSFD MINOK <br />CONTOURS <br />P20POSED <br />WATEfd MNIN <br />PROPOSED SANITA�iY <br />SEWER <br />FxiSTiN� <br />STORM SEWER <br />EXISTWG GAS <br />MAIN <br />EwSTING BURIFD <br />TELEPHONE <br />EXISTING <br />SANITARY SEWER <br />EXISiING <br />WATEKMAIN <br />�oT��NF <br />MARK � DATE � DESCRIPTION <br />°ArE 10/31/2014 <br />ISSUED= <br />sSUE REVIEW <br />PYIASE <br />PROJECT TITLE�. <br />hOME2 � <br />HAMPTON INN <br />�Ro�ecr owNeR: <br />TORGERSON <br />PROJECT LOCA�ION: <br />ROSEVILLE, MN <br />SHEET TIiLE <br />UTILITY PLAN <br />0 IS 30' 60' <br />' x 7 - I" = 60' <br />22 x34'_ I"=30' <br />��OJEC� 24277 <br />NUMBER <br />NSMBER C400 <br />