My WebLink
|
Help
|
About
|
Sign Out
Home
pf_01704
Roseville
>
Planning Files
>
Old Numbering System (pre-2007)
>
PF1000 - PF1999
>
1700-1799
>
pf_01704
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/28/2016 2:12:12 PM
Creation date
1/27/2016 2:23:26 PM
Metadata
Fields
Template:
Planning Files
Planning Files - Planning File #
1704
Planning Files - Type
Variance
Address
2545 Hamline Ave N
Project Name
Rosepointe
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
146
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
.� <br />� <br />� <br />� <br />� <br />� <br />� <br />� <br />� <br />� <br />�� <br />LJ <br />� <br />�� <br />� <br />303.600 Settina Hydrants <br />300-12 <br />$ydrant� shall be looated a� directed by the Engineer or his <br />represeatative and ahall be placed as shoti+n on the Standard Details of <br />the plan$. After each hydrant has been set, there sha11 be placed <br />around the base of the hydrant, at least one-out►ia yard oP e�s�rse <br />gravel or crushed rook. A layer of four.mil-thio).c polyethelene aha11 <br />be carePully plaaed ovar the rock to prevent baok�Pill material entering <br />the v�tds in th� roek drain. All hydrants muat b�e maintained in a <br />plum`b position. Hydrant extensions shall be used with the Eraglneer'� <br />�ons�ant only. ' <br />303.700 Joint R�straint <br />R�tainer glands shall be used for jo,int re�traint ou all bends having a <br />dsflectian of 22 1/2 degrQea or greater, tee�, arosse9, pluga, valves <br />at the end � � a line, all hydr�nt val.ves� and all h�dranta. Restrai.ne�i <br />joints east onto the pipe by the raaziufaaturer (Lalc Tyton � Fast3te, <br />eta.), will be considered as being equ3va].ent to the u�e of re��iner <br />�ianda. IF retainer glands are n�ot ava��able, thrust blocki.a�r may be <br />used Witb appr�oval af the Water Uti.lity ir�speQtor. <br />The use of �ina aoa�ed tie rods suitabl�r attaohed by half-airele alamps <br />ciay be utilized With the Engineer°s permis�ion. <br />Where valves are loQated on dead finds, the valve►s may be tied or l�ggsd <br />a�cross the valves with tie rads. <br />Plugged tees and oro9aea Sn a atra±ght run do r�ot <br />For �gstraiasd �O�rit3� the number of f�et oP tied <br />be iti acaordana� aitb� the follo�ing table: <br />requlr� r�straint. <br />pipe requ�.red sha11 <br />
The URL can be used to link to this page
Your browser does not support the video tag.