Roseville Maintenance Facility Report
<br />Summary of all Schemes
<br />102617.13
<br />Schemes A, B, C & D propose progressively larger additions to the existing site. The additions enlarge the
<br />vehicle storage and mezzanine space. In terms of circulation and cost efficiency, each addition adds less
<br />and detracts more from the existing design. The comparison chart below outlines the benefits of each
<br />Scheme. All program areas are represented by square footages. Numbers in green are greater than the
<br />existing and red represents proposed areas that are smaller than the existing.
<br />Roseville Maintenance Facility Site
<br />Options Summary
<br />Existing
<br />Facility
<br />Scheme A
<br />Scheme B
<br />Scheme C
<br />Scheme D
<br />Scheme E
<br />New Offsite
<br />Storage
<br />SW Addition
<br />+ Mezzanines
<br />W Addition +
<br />Mezzanines
<br />Combined
<br />Addition +
<br />Mezzanines
<br />New Building
<br />on 12 -acre
<br />New Site
<br />Vehicle Storage
<br />41,800
<br />41,800
<br />49,500
<br />56,600
<br />63,000
<br />59,700
<br />Wash Bay
<br />900
<br />900
<br />900
<br />900
<br />900
<br />1,600
<br />Repair Bay
<br />3,800
<br />3,800
<br />3,800
<br />3,800
<br />3,800
<br />11,300
<br />Meter/Sign Shops
<br />900
<br />900
<br />1,000
<br />2,100
<br />2,200
<br />4,200
<br />Mezzanine
<br />4,500
<br />9,100
<br />13,700
<br />12,700
<br />15,600
<br />10,700
<br />Storage
<br />2,600
<br />2,600
<br />2,600
<br />2,600
<br />3,200
<br />1,600
<br />Offices/Locker
<br />Rooms
<br />7,300
<br />7,300
<br />7,300
<br />7,300
<br />7,600
<br />10,900
<br />Total Off -Site
<br />Storage*
<br />18,000
<br />18,000
<br />9,200
<br />5,800
<br />0
<br />0
<br />Total Usable
<br />Building (SF)
<br />61,800
<br />66,400
<br />78,800
<br />86,000
<br />96,300
<br />100,000
<br />Yard Space
<br />1.35 acres
<br />1.35 acres
<br />1.35 acres
<br />1.35 acres
<br />1.35 acres
<br />5.67 acres
<br />Total Site
<br />3.98 acres
<br />3.98 acres
<br />3.98 acres
<br />4.3 acres
<br />4.3 acres
<br />12 acres
<br />"Off -Site Storage includes all equipment stored in a rented off-site building as well asvehicles and equipment stored in the Fire Department and City Hall.
<br />Move to New Site
<br />Scheme E is included in the comparison above. This final option explores moving the Maintenance
<br />Facility to a new site and is outlined in the next section of this report. Many opportunities exist in
<br />building or purchasing a new building. Vehicle stalls can be efficiently designed into the spacing of
<br />structural columns. Modern vehicle sizes and radii can be accommodated. With the right site, future
<br />expansion can be planned in the original building design.
<br />KODET ARCHITECTURAL G ROU P, LTD. 15 Groveland Terrace, Minneapolis, MN55403+1154 T:(612)377-2737