My WebLink
|
Help
|
About
|
Sign Out
Home
CCP 09222025
Roseville
>
City Council
>
City Council Meeting Packets
>
2025
>
CCP 09222025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/21/2025 3:01:44 PM
Creation date
10/21/2025 3:01:18 PM
Metadata
Fields
Template:
Roseville City Council
Document Type
Council Agenda/Packets
Meeting Date
9/22/2025
Meeting Type
Regular
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
447
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RCA Attachment 4 <br />I NTEROFFICE M EMORANDUM <br /> <br />Date: September 17, 2025 <br />To: Bryan Lloyd, Senior Planner <br /> <br />From: Jennifer Lowry, Roseville City Engineer <br />RE: Cleveland Club Third Addition Preliminary Plat <br />The Public Works Department reviewed the proposed plans for the project noted above and offer <br />the following comments with regard to the prƚƆĻĭƷƭ źƒƦğĭƷ ƚƓ /źƷǤ ƭĻƩǝźĭĻƭ ğƓķΉƚƩ <br />infrastructure: <br />1.Site Plan <br />p Due to the minimal amount of lots created (a simple lot split), the development <br />did not meet the threshold per City policy to conduct a traffic study. Circulation <br />and parking review will be provided later in the process. <br />p Connection to city streets would be via existing access points that were previously <br />reviewed and a part of the Agreement for Reciprocal Easement and Restrictive <br />Covenant (Ramsey Cty Doc # A04552813). <br />p Safe and direct pedestrian connections from Cleveland Avenue and Twin Lakes <br />Parkway should be provided. <br />p If setbacks, easements, or lot sizes change, the changes will need additional <br />review. <br />2.Utilities <br />p Water <br />Watermain is available for connections. <br />Final construction plans will be approved by the City prior to issuing <br />permits. <br />MDH Water Permit may be required. <br />p Sanitary <br />Sanitary sewer main is available for connections. <br />If the new buildings have commercial kitchens, be aware that the City has <br />a FOG ordinance that requires a 1000 gallon grease interceptor. <br />Final construction plans will be approved by the City prior to issuing <br />permits. <br />p Storm Sewer <br />The development has to meet city stormwater standards. Submittals from <br />ƷŷĻ ķĻǝĻƌƚƦĻƩƭ ĭƚƓƭǒƌƷźƓŭ ĻƓŭźƓĻĻƩ Ǟźƌƌ ĬĻ ƩĻǝźĻǞĻķ ğŭğźƓƭƷ ƷŷĻ ЋЉЊЏ <br />stormwater report, current standards, and what is being proposed. <br />Qbhf!25!pg!558 <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.