My WebLink
|
Help
|
About
|
Sign Out
Home
ord_190
Roseville
>
City Council
>
City Council Ordinances
>
0100
>
ord_190
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2007 9:03:52 AM
Creation date
4/22/2005 12:50:05 PM
Metadata
Fields
Template:
Roseville City Council
Document Type
Council Ordinances
Ordinance #
190
Ordinance Title
Building Code. An ordinance regulating all matters pertaining, relating or incidental to and the construction, building, alteration, repair, installation, performance, maintenance and inspection of all buildings, walks, structures, driveways, signs
Ordinance Date Passed
7/20/1954
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
66
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />25 <br /> <br />6-220 All pilot burners shall be supported in such a. manner that their posi- <br />tion relative to the main burner or burners will remain fixed. <br /> <br />6-221 Pilot lines shall be connected to vertical supply lilles when possible. <br />When horizontal line is used, connection must be made on top or side. <br />Connection must be ahead of all controls including regulator and <br />appliaace shut-off and shall be provided with a separate shut-off <br />cock. 'Where gas pressure is greater than that for which pilots are <br />designed a pressure regulator (pilot regulator) must be installed on <br />the downstream side of pilot line shut-off cock. <br /> <br />6-222 A shut-off cock must be installed on branch line to safety pilot and <br />to each branch line to plain pilot system. <br /> <br />6-223 A manually operated approved shut-off cock shall be installed adjacent <br />to the gas burner on the down stream of all other control valves either <br />manual or automatic. Such cock shall be so located that it is readily <br />accessible and shall clearly indicate the lion" and "off" position, or <br />direction of rotation to open or close. This valve or cock must have <br />hamtle securely attached in such a manner that it may not be readily <br />removed. When gas pressures are greater than 1 psig the cock must be <br />of the lubricated plug type. Gate or gloVe type valve will not be <br />acceptable. Provide bIecidel'! line or other approved method of insuring <br />against gas leakage to boiler during shur down periods. <br /> <br />6-224 A manually operated approved type lubricated shu:b-off cock shall be <br />installed at each boiler or furnace ahead. of all control valves aDd <br />regulators except pilot line. This cock shall be so located that it is <br />readily accessible and shall clearly indicate the on or off position or <br />direction of rotation to open and close. Cock shall be provided with a <br />suitable operating handle permaneitly attached. Gate or globe valve <br />will not be acceptable.. <br /> <br />6-225 Electric control valves shall be installed according to the instructions <br />furnished by the manufacturer. <br /> <br />6-226 All electrical connections shall be made in conformity with the provis- <br />ions of. all codell relating to the installation of electric wiring wi thin <br />the municipality. <br /> <br />6-227 A gas pressure regulator approved by the Heating Inspector shall be <br />installed on all gas burner installations. <br /> <br />6-228 Each boiler or fumace shall be equipped with safety devices to limit <br />high steam pressures or watjr temperatures, low-water level and high <br />air temperatures. Where boiler or furnace is equipped with so-called <br />power burner, where air for combustion is furnished by means other than <br />a natural draft stack or where boiler b111"llers are so sized and designed <br />to require forced or induced draft or both, the gas and air supply shall <br />be equipped' with suitable controls to prevent functioning of the gas <br />supply until air supply is adequate for proper combustion, or in the event <br />of failure of air supply to shut off the gas supply. <br /> <br />6-229 Where forced draft equipment is used, a manual cutout control switch may <br />be installed subdect to approval, to eemit lighting off the burner under <br />natural draft, normal opera'tion under forced draft to remain under safety <br />control. <br /> <br />-50- <br />
The URL can be used to link to this page
Your browser does not support the video tag.