Laserfiche WebLink
<br />all exterior walls and shall be one or more of the following materials: <br /> <br />Wood not less than three-fourths inch (3/411) thick. <br />Fiberboard not less than twenty five-thirty seconds inch (25/3211) <br />thick complying with U. B.C. Standard No. 22-l-61. <br />Plywood not less than one-half inch (1/211) thick complying with <br />U. B. C. Standard. <br />Insulated Strong board (brand name) or equivalent not less than <br />one-half inch (1/2 II) thick. <br /> <br />Section 2802 (b). Protection of Adjoining Property. <br /> <br />Any person making or causing an excavation to be made a depth of <br /> <br />twelve feet (121) or less, below grade. shall protect the excavation <br /> <br />so that the soil of adjoining property will not cave in or settle and <br /> <br />may be liable for the expense of underpinning or extending the foundation <br /> <br />of building on adjoining property where his excavation necessitates <br /> <br />such work. <br /> <br />Section 2507 (a) 4. Spacing. Spacing shall be amended <br /> <br />to require sixteen inches (1611) in one-story detached buildings of Group <br /> <br />j Occupancy. <br /> <br />Section 2515 (e) Plywood Subflooring. Shall be amended so <br /> <br />as to require all plywood, where used as structural subflooring. to be a <br /> <br />minimum thickness of five-eighths inch (5/811) or greater if required <br /> <br />in Table No. 25-n. <br /> <br />Section 2515 (f) Plywood Roof Sheathing. Shall be amended <br /> <br />so as to require all plywood, where used as structural roof sheathing, <br /> <br />to be a minimum thickness of one-half inch (1/211) or greater if required <br /> <br />in Table No. 25-0. <br /> <br />-2- <br />