Laserfiche WebLink
APPENDIX D <br />D103S NYre appara4cs access road gates. Gates securingthe <br />fire apparatus access marls shalt comply with all of the fo(tow- <br />ing criteria: <br />1. The minimum gate width shall be 20 feet (6096 mm). <br />2. Gates shall be of the swinging or sliding type. <br />3. Constmction of gates shall be of materials that allow <br />manual opemkioa by one person. <br />4. Gate components shall he maintained in an operative <br />condition at all times and replaced orrepaimd when de- <br />fective. <br />S. Electricgates shall be equipped withameans ofopening <br />dte gate by 5re deparmrent personnel for emergency ac- <br />cess. Emergency opening devices shall be approved by <br />the code official. <br />6. Manual opening gates shall notbe locked withapadlock <br />or chain and padlock unless they are capable of being <br />opened by means of forcible entry tools and <br />7. Locking device specifications shall be submitted for ap- <br />proval by the code official. ' <br />D103.6Signs. Whemmquimd bythe code official, fire appara- <br />tus access roads shall be marked with permanent NO <br />PARKING~IRE LANE signs eomgl; ing with Figuee <br />D 103.6. Signs shag have a minimum dimension of 12 inches <br />(305 mm)wideby ISinches(457mm)high and have red letters <br />on a white reflective background Signs shall be posted on one <br />or both sides of the fim apparatus road as required by Section <br />0103.6.1 or 0103.62. <br />SIGN TYPE'A" SIGN TYPE "C" SIGN TYPE "D" <br />NO ND NO <br />PARKING PARKING PARKNG <br />18" <br />FIRE LANE FlRE LANE FIRE LANE <br />~~ f~ <br />-12"-~-~ ~.--12"---.~ ~.-12"--~ <br />FIGURE D1o3.6 <br />FIRE LANE SIGNS <br />0103.6.1 Roads 20 to 26 feet in width. Fire apparatus no- <br />case roads 20 to 26 feet wide (6096 m 7925 mm) stall be <br />posted on both sides as a fire lane. <br />0103.6.2 Roads more than 26 feet in width. Fire appara- <br />tus access roads mom than 26 feet wide (7925 mm) to 32 <br />feetwide (9754 mm} stall beposted an one side ofthe road <br />as s fire lane. <br />SECTION 0104 <br />COMMERCIAL AND INDUSTRIAL DEVELOPMENTS <br />0104.1 BnOdings exceeding three storiesl30 feet m height. <br />Buildings or facilities exceeding 30 feet (9144 mm) or three <br />FeRE APPARATUS ACCESS ROADS <br />stories in heightsha0haveak leastthaeemeans office apparatus <br />access for each structure, <br />0104.2 Buildings exceeding 62,000 square feet in aria. <br />Buildings or facilities havingagross buildingareaofmore than <br />62,000 square face (5760 m') shalt be provided with two sepa- <br />rate and approved fire apparatus access roads. <br />Exception: Projects having a gross building area of up to <br />124,000 square feet (11 S20 m2) bavsng a stogie appmved <br />fire apparatus access road when all buildings are equipped <br />throughouf wntir approved automatic sprinkler systems. <br />01043 Remoteness. Where two access roads am required, <br />they shall be placed a distance apart equal to not less than one <br />half of the length ofOte maximum ovemlI diagonal dimension <br />ofdte property or area to be served, measured in a straight line <br />between accesses. <br />SECTION 0905 <br />AERIAL FIRE APPARATUS ACCESS ROADS <br />DI05"I Where required.Buildings orportions of buildings or <br />;acilities exceeding3C feet (9144 rem) iv rreighiabove the low- <br />est level of fire department vehicle access shall be provided <br />with approved fire appamms access roads capable of accom- <br />modating fire departrnent aerial appamms. Overhead utility <br />and powerlines shall notbe located within the aerial fire appa- <br />mtusaccess roadway. <br />0105.2 Width. Fire appazalus access roads shall Lave amini- <br />mum unobstmcted widtfi of26 feet (7925 mm) in ffie immedi- <br />amvicinity of any building orportion of building more than 30 <br />feet (9I44 mm) iv height <br />01053 Promtmity to bu0ding.At least one ofthe regaimd ac- <br />cess routes meeting this condition shall be located within a <br />minimum of IS feet (4372 mm) and a ruaximum of 30 feet <br />(9144 mm) from the bmldmg, and shall be positioned parallel <br />to one entire side of the building. <br />SECTION 0706 <br />MULTIPLE-FAMILY RESIDENTIAL DEVELOPMENTS <br />0106.1 Projects having more than 100 dwelliagnnits. Mut- <br />8ple-familyresidential projectshaving morethan 100 dwelling <br />units shall be equipped throughom with two separate and ap- <br />pmved fire appazams access marls. <br />Exception: Projects having up to 200 dwelling units may <br />have a single approved fire apparatus access road when all <br />buildings, includmg nonresidential occupancies, aze <br />equipped throughout with appmved automatic sprinkler <br />systems installed in accordance with Section 903.3.1.1 or <br />903.3.1.2 of thelntematianal Fire Cade_ <br />0106.2 Projects Laving more than 200 dwelling nnifs. Mul- <br />tiple-fatni]yresidentialpmjectshnving more than200 dwelling <br />units shall be provided withtwo separate and approved fire ap- <br />parakus access roads regardless of whether they are equipped <br />with an approved amomatic sprinkler system <br />362 20001NTERNATIONAL FlRE CODE® <br />