My WebLink
|
Help
|
About
|
Sign Out
Home
2005_0822_Packet
Roseville
>
City Council
>
City Council Meeting Packets
>
2005
>
2005_0822_Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/9/2014 9:16:46 AM
Creation date
9/14/2009 10:04:07 AM
Metadata
Fields
Template:
Roseville City Council
Document Type
Council Agenda/Packets
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
394
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
- - _ "-' -- = �= - <br />_i.: . ' <br />' �rR _ _ . � . . . <br />.�ti�: . . <br />• ,va,i��. - <br />. ... <br />SF1'.i.� Far.t Sh����i l. �._ ��' .-.. � � ... <br />��I�t=1: ? I, i�7�3 ' ._ `. , . . .--- • — <br />�.• =1' ' :.l � ._ . . . : t �.t+��� � . <br />1 l. Weeds, grass, brush, trash and other combustible materials shall be kept at least 10 feet from an <br />AST. <br />12. ASTs shall have a minimum 3-foot separation between tanks. Larger tanks may require more <br />space. <br />13. Storage vessels for LP-gas and CNG shall be located 20 feet or more from .AST's. Suitable means <br />shall be provided to prevent the accumulationof liquids under adjacent LP-gas containers such as <br />by dikes, diversion c�,tz�bs or grading. When A,S'�" s are within a diked area, the LP-gas containers <br />shall be outside the diked area and at least 10 feet away from the centerline of the wall or the <br />diked area. <br />14. ASTs shall have warning signs or labels to identify the tank contents to emergency personnel <br />15. ASTs require normal and emergency vents. The normal vent shall terminate at least 12 feet above <br />the ground level and 5 feet from building openings or property lines that can built upon. <br />16. Electrical equipment shall be installed in accordance with the Minnesota State Electrical Code. <br />17. Dispensing is required to be under the supervision of a qualified attendant at all times. The <br />attendant's primary function shall be to supervise, observe and control the dispensing of motor <br />fuels. The attendants view to the dispensing area shall be unobstructed. The attendant shall <br />prevent the dispensing of flammable and combustible liquids and flammable gases into containers <br />not in compliance with the Minnesota State Fire Code. The attendant shall also control sources of <br />ignition, give immediate attention to accidentalspills or releases, and be prepared to use fire <br />extinguishers. A method of communicating with the fire department shall be provided for the <br />attendant. <br />1$. Contact the State Fire Marshal Division for requirements that may apply to situations such as: <br />• Dispensing at a bulk plant, marina or . Dispensing of LPG, CNG, etc. <br />resod . Dispensing from tank vehicles <br />• Dispensing inside a building Unsupervised dispensing <br />• Dispensing into containers <br />19. Pages 4, 5, and 6 of this ir�formatioz� sheet contain additional requirements specific to the type of <br />above ground tank installation used for dispensing. <br />
The URL can be used to link to this page
Your browser does not support the video tag.