My WebLink
|
Help
|
About
|
Sign Out
Home
CC_Minutes_2010_1108
Roseville
>
City Council
>
City Council Meeting Minutes
>
201x
>
2010
>
CC_Minutes_2010_1108
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/14/2010 2:04:27 PM
Creation date
12/14/2010 2:04:18 PM
Metadata
Fields
Template:
Roseville City Council
Document Type
Council Minutes
Meeting Date
11/8/2010
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
63
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ROSEVILLE FIRE STATIONS BUILDING CONDITION OBSERVATIONS <br /> 1 I 1 <br /> e <br /> ,'5 <br /> Vtt YE L <br /> 4 £S 1 4 <br /> s y <br /> U ii <br /> Station 1 Lexington <br /> 1. Building Code /OSHA /ADA Access Compliance. <br /> Restrooms, door hardware not compliant. <br /> Clearance between trucks and turn out gear is an unsafe OSHA issue. <br /> Trip hazards at entrance doors. <br /> No elevator. <br /> 2. Healthy Environment/IAQ (Indoor Air Quality) control moisture and <br /> ventilation for pollutant control/comfort. <br /> Mold from leaking roof above ceiling and i n ce tile. <br /> Floor drain back ups in basement. <br /> Poor drainage away from building. <br /> Below grade water pressure coming up through slab in basement. <br /> Mold has made the building dangerous to inhabit. <br /> 3. Functional plan /equipment potential for adaptability and expansion. <br /> Not all bays are drive through. <br /> Watch room location not current for functionality. <br /> li lgr Hose tower not functional, ladder is not legal. <br /> Laundry in hose tower. <br /> Men/Women restrooms are too small. <br /> i s <br /> 4. Total building energy use. Insulation, mechanical and electrical systems. <br /> Overhead doors do not seal. <br /> Mechanical and electrical systems are dated and at end of life cycle. <br /> No emergency generator (broken). <br /> Building has little or no insulation. <br /> 5. Sustainable environment. Structure, operation and maintenance costs, <br /> finishes. <br /> Wood construction, 90 years old. <br /> Roof is failing and needs replacement. <br /> Finishes are worn. <br /> Structural cracking. <br /> •UET ©W ASSOCIATES AN ARCHITECTURAL SERVICE CO/ARANY Iffl <br /> 2348 RICE STREET SUITE 210 ST. PAUL MINNESOTA 53113 TELEPHONE (AS11 401 -8701 <br />
The URL can be used to link to this page
Your browser does not support the video tag.