Laserfiche WebLink
LEGEND <br />STORM MANHOLECABLE UNDERGROUND LINE <br />ELECTRIC OVERHEAD LINE <br />CATCH BASIN <br />ELECTRIC UNDERGROUND LINE <br />CURB INLETFIBER OPTIC UNDERGROUND LINE <br />NATURAL GAS UNDERGROUND LINE <br />FLARED END <br />SANITARY SEWER PIPE <br />SANITARY MANHOLESTORM SEWER PIPE SOLID WALL <br />STORM SEWER PIPE DRAINTILE <br />HYDRANT <br />TELEPHONE UNDERGROUND LINE <br />GATE VALVE & BOXWATERMAIN PIPE <br />107 <br />WATER SHUTOFF <br />STRUCTURE DETAIL FORSTRUCTURE DETAIL FOR <br />REMOVE AND DISPOSE OF EXISTING STORM <br />C5.0C5.1 <br />SEWER TO EXISTING MANHOLE & GROUT HOLE. <br />LIGHT POLE <br />CASTING DETAIL FOR <br />CONSTRUCTION DETAIL FOR <br />116 <br />ALL YARD DRAINS UNLESS <br />C5.0C5.1 <br />UNLESS OTHERWISE NOTED.OTHERWISE NOTED. <br />8 <br />STRUCTURE DETAIL FOR <br />ALL 2' x 3' CBMH <br />C5.1 <br />2' x 3' CB <br />R-3067 <br />R-3067 <br />RIM=934.85 UTILITY NOTES <br />2' x 3' CB <br />RIM=934.85 <br />INV=930.85 <br />R-3067 <br /> R-3067 <br />INV=930.85 <br />RIM=934.85 <br />RIM=934.85 <br />INV=930.31 <br />INV=931.65 <br />1.It is the responsibility of the contractor to perform or coordinate all necessary utility connections and <br />relocations from existing utility locations to the proposed building, as well as to all onsite amenities. <br />These connections include but are not limited to water, sanitary sewer, cable TV, telephone, gas, <br />69 LF 12" RCP @ <br />electric, site lighting, etc. <br />0.96% <br />16 LF 8" <br />2.All service connections shall be performed in accordance with state and local standard specifications <br />HDPE <br />for construction. Utility connections (sanitary sewer, watermain, and storm sewer) may require a <br />permit from the City. <br />6" HDPE <br />ROOF DRAIN3.The contractor shall verify the elevations at proposed connections to existing utilities prior to any <br />INV=927.40 <br />6" HDPE <br />demolition or excavation. <br />625 LF - 4" HDPE <br />INV=930.0 <br />ROOF DRAIN <br />ROOF DRAIN <br />ROOF DRAIN <br />DRAINTILE AT <br />6" HDPE <br />6" HDPE <br />6" HDPE <br />ROOF DRAIN <br />FOOTINGS <br />4.The contractor shall notify all appropriate engineering departments and utility companies 72 hours <br />R-3067 <br />INV=931.50 <br />INV=931.85 <br />INV=931.75 <br />6" HDPE <br />INV=931.0 <br />ROOF DRAIN <br />RIM=933.57 <br />prior to construction. All necessary precautions shall be made to avoid damage to existing utilities. <br />INV=931.5 <br />6" HDPE <br />INV=929.57 <br />R-2540 W/ GRATE <br />INV=931.00 <br />RIM=934.80 <br />5.Storm sewer requires testing in accordance with Minnesota plumbing code 4715.2820 where located <br />INV=930.19 <br />REFER TO ARCHITECTURAL <br />within 10 feet of waterlines or the building. <br />PLANS FOR EXACT LOCATION OF <br />ROOF DRAINS & DOWN SPOUTS. <br />6.HDPE storm sewer piping and fittings must meet materials and installation standards per Minnesota <br />INV=928.55 <br />plumbing code 4715.0420.6C(4) and 4715.0540.C including ASTM D3212 joint pressure test and <br />ROOF DRAIN <br />ASTM C2321 installation practices. <br />STORM INV=930.08 <br />6" HDPE <br />SAN INV=928.42 <br />INV=931.50 <br />INSULATE BETWEEN PIPES <br />7.All RCP pipe shown on the plans shall be MN/DOT class 3. <br />ROOF DRAIN <br />ROOF DRAIN 6" HDPE <br />8. <br />6" HDPE <br />INV=931.50 <br />INV=931.00 <br />ROOF DRAIN 6" HDPE <br />INV=931.00 <br />9. <br />48" <br />insulation (MN/DOT 3760) with a thermal resistance of at least 5 and a compressive strength of at <br />RIM=933.98 <br />DRAINTILE CONNECTION <br />INV=928.69 E <br />100 LF - 8" SDR 35 @DRAINTILE CONNECTION TO ROOF <br />TO ROOF DRAIN LEAD <br />INV=927.22 N, W <br />0.45%DRAIN LEADINV=931.0 <br />INV=931.0 <br />R-3067 <br />10.All watermain piping shall be class 52 ductile iron pipe unless noted otherwise. <br />RIM=931.90 <br />75 LF 15" RCP @ <br />INV=923.71 <br />0.96% <br />11.See Project Specifications for bedding requirements. <br />GRATE <br />R-2540 W/ GRATE <br />88 LF 18" RCP @ <br />R-2540 W/ GRATE <br />RIM=933.98 <br />RIM=933.98 <br />0.93% <br />RIM=933.98 <br />INV=929.00 RDINV=929.0 RD <br />12.Pressure test and disinfect all new watermains in accordance with state and local requirements. <br />INV=927.29 <br />INV=926.40 <br />INV=928.08 <br />SUMP=925.29 <br />SUMP=924.40 <br />13.Sanitary sewer piping shall be PVC, SDR-35 for depths less than 12', PVC SDR-26 for depths <br />62 LF 15" RCP @ <br />84 LF 12" RCP @ <br />2.24% <br />between 12' and 26', and class 52 D.I.P. for depths of 26' or more. <br />0.93% <br />R-2540 W/ GRATE <br />RIM=934.66 <br />14.Contractor shall finish grades around all existing and proposed gate valves to allow for exposed <br />INV=929.47 <br />access and finish grades around existing Hydrants shall be at bury line. <br />TEE <br />RIM=934.984 LF 15" HDPE @ 1.0% <br />RIM=935.10 <br />TEE <br />INV=927.64 E,W <br />INV=924.11 N,S <br />63 LF 15" RCP @ <br />0.75% <br />24" INSPECTION PORTS <br />24" MANIFOLD <br />R-2540 W/ SOLID LID <br />441 LF 8" DRAINTILE @ <br />RIM=934.80 <br />0.00% INV=924.66 <br />INV=926.81 N 15" HDPE <br />INV=924.66 N 8" D.T. <br />4 x 211 LF PERFORATED PIPES @ 0.00% <br />INV=924.56 S <br />INV=926.24 <br />INV=928.02 W <br />2' x 3' CB <br />WEIR WALL SEE DETAIL <br />R-3067-C <br />I hereby certify that this plan, <br />RIM=930.90 <br />INV=928.00 <br />specifications or report was prepared <br />by me or under my direct supervision <br />and that I am a duly licensed <br />9 <br />Professional Engineer under the laws <br />C5.1 <br />of the state of Minnesota. <br />Michael A Murphy, P.E. <br />Date: Reg. No.:05.17.1342808 <br />Rev.DateDescription <br />105.17.13Bldg. Permit Submittal <br />205.28.13City Submittal <br />306.05.13Bid Package #1 <br />12136036.000 <br />Project #: <br />Drawn By:SJM / CKJ <br />Checked By: <br />ZRE / MAM <br />Issue Date: <br />05.15.13 <br />Sheet Title: <br />UTILITY PLAN <br />Sheet: <br />NORTH <br />C4 <br />0 <br />102040 <br />Sheet:7ofof10 <br />M:\Projects\Projects - 2013\12136036- Lexington Station\C. Design\Drawing Files\12136036 C4 - Utility.dwg <br />ALL EXISTING ITEMS AND CONDITIONS SHOULD BE VERIFIED BY THE CONTRACTOR BEFORE CONSTRUCTION <br />