Laserfiche WebLink
<br />City of Arden Hills <br />Planning Commission Meeting for June 8, 2016 <br /> <br />P:\Planning\Planning Cases\2016\PC 16-014 - Land O' Lakes - PUD\Memos_Reports_16-014 <br />Page 6 of 15 <br /> <br /> Zoning Code Existing Proposed Phase 1 Future Phase 2 <br />Building Height 35’ 56’ --* 56’ <br />*No new structures are being constructed with Phase 1 of the project. The Master PUD and Phase 2 <br />of the project suggests a new 4 story office structure at approximately 56 feet in height. <br /> <br />F. Setbacks – Meets Requirements <br /> <br />The minimum building setbacks in the I-1 – Limited Industrial District include a 55 foot <br />front yard setback, 20 foot rear yard setback, 20 foot side yard setbacks, and a 50 foot side <br />yard corner setback where applicable. Although Phase 1 of the project does not include any <br />new structures, the Master PUD and future Phase 2 of the project includes a new office <br />building. As proposed, the new structure proposed in Phase 2 of the Master PUD will meet <br />all setback requirements. <br /> <br /> Permitted Existing Proposed Phase 1 Future Phase 2 <br />Front Yard Setback 55’ 400’ --* 390’ <br />Rear Yard Setback 20’ 436’ --* 436’ <br />Side Yard Setback (East) 20’ 103’ --* 103’ <br />Side Yard Setback (West) 20’ 561’ --* 561’ <br />Side Yard Corner (East) 50’ 619’ --* 619’ <br />*No new structures are being constructed with Phase 1 of the project. The Master PUD and Phase 2 of the <br />project suggests a new 4 story office structure. <br /> <br /> <br />Section 1325 – General Regulations <br /> <br />A. Tree Preservation – Meets Requirements <br /> <br />The applicant submitted a Tree Survey and Tree Replacement Plan as part of their tree <br />preservation and mitigation requirements (Attachment B). The following table outlines these <br />numbers and the additional requirements of the tree preservation ordinance pertaining to tree <br />removal and tree mitigation regulations. <br /> <br />Development of the site as proposed in the Master PUD requires extensive tree removal. The <br />applicant has stated their intent to expand the Land O’Lakes Campus in such a way that <br />preserves as many high quality trees as possible, knowing that many of the significant trees <br />will have to be removed in order for the property to accommodate the expansion of the <br />Campus. During Phase 1 of the project, approximately 140 trees will be planted within the <br />construction boundary of the south parking lot. Based on the proposed tree removal for both <br />phases of the project, the City’s Tree Preservation Ordinance requires 2,000 caliper inches of <br />tree plantings. At this time, the application is proposing a total of 2,475 caliper inches or 745 <br />trees. <br />