Plan Review Comments <br />Page 1 of 1 <br /> <br /> <br />Plan Review Comments <br /> <br />Date: June 13, 2016 <br />Project: Land O’Lakes – Phase II Final PUD <br />Address: 4001 Lexington Avenue North <br /> <br />Comments <br /> <br />1. Remove the following plans from the Phase II Final PUD plan set: <br />• Phase I Demolition Plan (C01-01) <br />• Phase I Grading & Erosion Control Plan (C02-01) <br />• Phase I Utility Plan (C03-02) <br />• Phase I Paving and Geometric Plan (C04-01) <br />• Phase I Stormwater Mangement Plan (C05-01) <br />• South Parking Lot Photometric Plan (EL01-01B) <br /> <br />2. The westerly access on County Road F will be restricted to a ¾ access by <br />Ramsey County where lefts in are prohibited. A supplemental plan for a “pork <br />chop” median that will prevent lefts in at this access should be provided. <br /> <br />3. Lake Johanna Fire Department review and approval of main parking lot access <br />from east entrance driveway shall be required. <br /> <br />4. Section 1325.03, Subd. 3 (B) of the Zoning Code states that roof-mounted <br />mechanical equipment shall be excepted from the height limitations if the <br />enclosures do not extend more than 12 feet above the roof upon which they are <br />located. The proposed mechanical equipment installation on the new corporate <br />office building would be 15 feet – 6 inches above the roof line. Project narrative <br />should be update to include this as an area where flexibility is needed through <br />the PUD process. <br /> <br />5. Provide details on the total length of the walking trails and the proposed surfacing <br />material. <br /> <br />6. Provide updated legal description for water main easement based on new <br />location. Existing water main easement will need to be vacated by City Council <br />concurrently with their review of the Phase II Final PUD application. <br /> <br /> <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.