Laserfiche WebLink
SECOND FLOOR903'-6"LANDING905'-10"A252A <br />A255 <br />A254 A267 <br />A253266B206A <br />B206B <br />B206C <br />B206D <br />B202A <br />B216AB202B <br />B208AA252CA252D <br />B219BB208CB208B B210 B219CB208B-1 <br />B208C-1 <br />48"210CCONFERENCE209B208EOFFICE208FWORKRM208DOFFICE208COFFICE208BOFFICE208AOFFICE208OFFICEBUSINESS208IOFFICE208HOFFICE208GTELLERS208JSAFE206OFFICE205AOFFICE207DESIGN STUDIOCC200OfficeRoosaWayne201FILM LABPHOTO/202DARKROOMPHOTO LAB/BLACK & WHITE200AGALLERYJOHNSON203ALABCOLOR PHOTO203BOFFICECC234AOFFICE200BOFFICE234STUDIO204STUDIO235STUDIOCC209AOFFICECIO210BINTERVIEW210CENTERGUESTADMISSIONS210CINTERVIEWICE254OFFICE253OFFICE252WAITING251RECEPTIONNCE201LOUNGE248CORRIDOR250STORAGEFOOD SERVICE2ST4STAIR #4275LANDING273ATRIUM276VESTIBULEEAST279STORAGE284ENTRYEXIST.274VESTIBULEWEST249ASTORAGEUP <br />UP <br />UP <br />DN <br />OPEN TOBELOWOPEN TOBELOWUPUPUPDN <br />DN <br />DN <br />DN <br />UP <br />UP <br />DN <br />RAMP UP <br />DN <br />UP <br />DN <br />RAMP UP <br />DN <br />D N <br />RAMP DOWN <br />DN <br />RAMP DOWN <br />DN <br />DN <br />D <br />N <br />DN <br />UP <br />DN <br />DN <br />UP <br />UP <br />UP <br />DN <br />UP <br />UP <br />UP <br />D <br />N <br />UP <br />DN <br />UP <br />UP <br />UP <br />UP <br />UP <br />DN <br />DN <br />DN A3352.1342KD~HF~5E~06A3352.1342KD~HF~5E~06A3352.1342KD~HF~5E~06A3352.1342KD~HF~5E~06EX <br />EX <br />EA <br />EX <br />HEHE <br />ED <br />EXED <br />EXEDNO WORK IN BCEX <br />CLC AC/BC/CC <br />AC/BC/CC <br />CLC <br />EA EA <br />EA <br />20 OCC <br />ED <br />29 OCC <br />13 OCC <br />EA <br />SEATING - 13 OCC <br />129' DIA <br />G <br />O <br />NAL A <br />60' >1/3x 129 ' D I A G O N A L A -O K <br />NO HAZARDOUS <br />MATERIALS ARE USED <br />WITHIN THIS LAB <br />AS DISCUSSED IN A MEETING ON 1/11/18 W/ <br />DAVE SCHERBEL, BUILDING OFFICIAL, THE <br />COMPLIANT NUMBER OF EXIT ACCESS POINTS <br />AND COMMON PATH OF TRAVEL SATISFIES THE <br />REQUIREMENTS FOR MEANS OF EGRESS FROM <br />THIS AREA. THE TWO EXIT ACCESS POINTS TO <br />THE CORRIDOR SATISFY THE EGRESS <br />REQUIREMENTS FROM THE ROOM AND TWO <br />SEPARATE MOE ARE NOT REQUIRED FROM THE <br />DEAD END CORRIDOR <br />AC-274 <br />OPTICAL <br />ENGINEERING LABAC-253 <br />MEN <br />AC-252 <br />WOMEN <br />AC-251 <br />CUSTODIAL <br />AC-248 <br />ELECTRICAL <br />ENGINEERING <br />COMMON PATH 80'<100' OK <br />21 OCC <br />15 OCC <br />10 OCC 231' DIAGONAL D9 3 ' >1 /3 x2 3 1 ' D IA G O N A L D -O K <br />OPEN TO ABOVE PERMITTED <br />PER MBC 712.1.8 <br />COMMON PATH FROM NW CORNER EXTENDS TO HERE <br />PRIOR TO COMPLETION OF PHASE 3 - 95' < 100' - OKAY <br />CONTROL AREA <br />CLC-2A <br />75% MAQ ALLOWED <br />ENTIRETY OF AC-BC BUILDING <br />SECOND LEVEL IS CONTROL AREA <br />AC/BC 2/3A, 50% MAQ ALLOWED <br />AC-247 <br />MODERN PHYSICS <br />LAB <br />CC-2XX <br />VESTIBULE <br />CC-229 <br />OFFICE - 9 <br />CC-228 <br />OFFICE - 8 <br />CC-227 <br />OFFICE - 7 <br />CC-226 <br />OFFICE - 6 <br />CC-225 <br />OFFICE - 5 <br />CC-224 <br />OFFICE - 4 <br />CC-222 <br />OFFICE - 3 <br />CC-221 <br />OFFICE - 2 <br />CC-218 <br />OFFICE - 1 <br />CC-216 <br />TESTING AC-219 <br />TESTING <br />? <br />? <br />AC-152 <br />Room <br />AC-279 <br />ELEVATOR LOBBY <br />AC-170 <br />CORRIDOR <br />AC-172 <br />CORRIDOR <br />AC-240G <br />OFFICE <br />AC-240C <br />OFFICE <br />AC-240H <br />OFFICE <br />AC-238 <br />DIV <br />AC-240K <br />OFFICE <br />AC-240E <br />OFFICE <br />AC-240L <br />OFFICE <br />AC-240J <br />OFFICE <br />AC-240F <br />OFFICE <br />AC-241 <br />RESEARCH - <br />TELECONFERENCE <br />CC-230 <br />RESEARCH <br />CC-232 <br />HAPPY LAB <br />CC-231 <br />OFFICE <br />AC-2XX <br />CIRCULATION <br />EA <br />EA EA <br />AC-276 <br />INTRO TO <br />PHYSICS <br />AC-266 <br />RESEARCH - <br />ROBOTICS <br />AC-271 <br />ENGINEERING 1 <br />(FLUIDS)AC-273 <br />FLEX LAB AC-275 <br />ENGINEERING 2 <br />(MATERIALS) <br />AC-250 <br />CONFERENCE <br />ROOM <br />AC-280 <br />ELEC/DATA <br />AC-278 <br />STORAGE <br />AC-284 <br />ELEV. <br />AC-286 <br />SHAFTAC-288 <br />HUDDLE <br />AC-285 <br />BIO CHEM <br />RES/STORAGE <br />AC-293 <br />BIO CHEM INST. <br />EA <br />EA EA <br />AC-291 <br />BIO CHEM <br />RESEARCH 1 <br />AC-287 <br />BIO CHEM <br />RESEARCH 2 <br />AC-283 <br />INORGANIC AND <br />PHYS CHEM <br />AC-281 <br />STAIR <br />AC-293 <br />LOUNGE <br />AC-295 <br />BIO CHEMISTRY <br />LAB <br />EA <br />EA EA <br />renovation in this <br />area in future <br />Phases still being <br />designed <br />27 OCC <br />9 OCC <br />5 OCC 5 OCC 1 OCC <br />24 OCC <br />10 OCC <br />EX <br />ED <br />AC/BC CC <br />EX ED <br />EA <br />EA <br />EA <br />EX <br />EX <br />ED <br />ED <br />EX <br />OPEN <br />STAIR <br />OPEN TO <br />BELOW <br />OPEN TO <br />BELOW <br />AC-276A <br />STORAGE <br />STANDPIPE <br />STANDPIPE SERVING <br />THIS SIDE OF H EXIT <br />LOCATED IN STAIR <br />NO HAZARDOUS <br />MATERIALS ARE USED <br />WITHIN THIS LAB <br />MBC 1015.1, ITEM 4 - EDUCATIONAL <br />LABORATORIES AND PREP ROOMS EXCEEDING <br />500 SF CONTAINING HAZARDOUS MATERIALS <br />SHALL HAVE 2 MOE <br />FIXED SEATING APPROXIMATELY 250 OCCUPANTS10 OCCUPANTS10 OCCUPANTS 10 OCCUPANTS10 OCCUPANTS 6 OCC <br />6 OCC <br />15 O <br />C <br />C <br />15 O <br />C <br />C <br />30 OCCUPANTS30 OCCUPANTS30 OCCUPANTS10 OCCUPANTS <br />10 OCCUPANTS <br />10 OCCUPANTS <br />10 OCCUPANTS <br />6 OCC <br />6 OCC <br />15 OCC <br />15 OCC <br />APPROXIMATE BALCONY/BOX <br />OCCUPANT LOAD <br />854 OCCUPANTS <br />APPROXIMATE LOBBY <br />OCCUPANT LOAD <br />304 OCCUPANTS <br />EA <br />EA <br />EA <br />EA <br />EA <br />EA <br />EA <br />EA <br />EAFIXED SEATING APPROXIMATELY 350 OCCUPANTSEX <br />EX <br />EA <br />EA <br />EA <br />EA <br />GRAND TOTAL OCCUPANT LOAD <br />SECOND FLOOR CLC INCLUDING ADDITION <br />1158 EXISTING OCCUPANTS <br />120 NEW OCCUPANTS <br />1278 TOTAL OCCUPANTS <br />4 MOE REQ'D <br />8 PROVIDED <br />(OCCUPANTS OF ADDITION ARE <br />CALCULATED TO EXIT INDEPENDENT OF <br />EXISTING BUILIDNG) <br />EX/EA 1 <br />EX/EA 2 <br />EX/EA 3 <br />EX/EA 4 <br />EX/EA 5 <br />EX/EA 7 <br />EX/EA 6 <br />EX/EA 8 <br />1158 EXISTING OCCUPANTS <br />6 EXISTING MOE PROVIDED <br />160 OCCUPANTS <br />DOOR - 160 X 0.2 = 32.00'' <br />STAIR - 160 X .3 = 48.00'' <br />160 OCCUPANTS <br />DOOR - 160 X 0.2 = 32.00'' <br />STAIR - 160 X .3 = 48.00'' <br />200 OCCUPANTS <br />DOOR - 200 X 0.2 = 40.00'' <br />STAIR - 200 X .3 = 60.00'' <br />200 OCCUPANTS <br />DOOR - 200 X 0.2 = 40.00'' <br />STAIR - 200 X .3 = 60.00'' <br />200 OCCUPANTS <br />DOOR - 200 X 0.2 = 40.00'' <br />STAIR - 200 X .3 = 60.00'' <br />200 OCCUPANTS <br />DOOR - 200 X 0.2 = 40.00'' <br />STAIR - 200 X .3 = 60.00'' <br />60 OCCUPANTS <br />DOOR - 60 X 0.2 = 12.00'' <br />STAIR - 60 X .3 = 18.00'' <br />60 OCCUPANTS <br />DOOR - 60 X 0.2 = 12.00'' <br />EA <br />AC/BC/CC <br />AC/BC/CCWALL CLASSIFICATIONAREA CLASSIFICATIONMEANS OF EGRESSCODE PLAN SYMBOLS <br />LEGEND <br />EXIT <br />EXIT DISCHARGE <br />EXIT ACCESS <br />EGRESS PATH <br />INCIDENTAL USE <br />SHAFT <br />HEALTHCARE SUITE <br />SMOKE BOUNDARY <br />FIRE WALL <br />OCCUPANCY SEPARATION <br />HORIZONTAL EXIT <br />1 HR FIRE RATED ASSEMBLY <br />WITH SMOKE PROTECTION <br />3 HR FIRE RATED ASSEMBLY <br />2 HR FIRE RATED ASSEMBLY <br />1 HR FIRE RATED ASSEMBLY <br />SMOKE PARTITION <br />1 HR FIRE RATED ASSEMBLY <br />(IBC 509) <br />SURROUNDING SYMBOLS INDICATE <br />RATING AND DAMPER REQUIRMENTS <br />SURROUNDING SYMBOLS INDICATE <br />RATING AND DAMPER REQUIRMENTS. <br />FIRE DAMPER REQUIRED AT BOTTOM <br />OF SHAFT <br />SURROUNDING SYMBOLS INDICATE <br />RATING AND DAMPER REQUIRMENTS <br />CLOSER, LATCH & GASKETS REQUIRED <br />FIRE PARTITION <br />FIRE AND SMOKE DAMPER <br />USUALLY REQUIRED <br />SEE IBC 1023 <br />FOR I-3 OCCUPANCY, SEE ALSO 408.2 <br />(FIRE BARRIER) <br />NOT ALL SYMBOLS MAY BE USED ON EACH PLAN. <br />2 HR FIRE RATED ASSEMBLY <br />WITH SMOKE PROTECTION <br />3 HR FIRE RATED ASSEMBLY <br />WITH SMOKE PROTECTION <br />(IBC 710) <br />(IBC 708) <br />'CORRIDOR WALLS' <br />'INCIDENTAL USE' <br />FIRE DAMPER USUALLY REQUIRED <br />FIRE DAMPER USUALLY REQUIRED <br />FIRE DAMPER USUALLY REQUIRED <br />FIRE AND SMOKE DAMPER <br />USUALLY REQUIRED <br />FIRE AND SMOKE DAMPER <br />USUALLY REQUIRED <br />SEE IBC 709, 717.5.5 <br /> LSC XX.3.7, 8.3 <br />EA <br />EX <br />EDFIRE RESISTANCE RATINGS'PROTECTION OF HAZARDS' (LSC XX.3.2) <br />'CONST. OF CORRIDOR WALLS' (LSC XX.3.6.2) <br />(IBC 706) <br />HORIZONTAL EXIT <br />DELAYED EGRESS <br />HE <br />DE <br />REFERENCES TO LSC (LIFE SAFETY CODE) "XX" REFERS TO CH 12 - <br />42. <br />FE <br />FV <br />FEC <br />FVCMISCELLANEOUS FIRE EXTINGUISHER CABINET <br />FIRE VALVE <br />FIRE EXTINGUISHER <br />FIRE VALVE CABINET <br />PROJECT LIMITS LINE <br />SEE IBC 509, 711 <br /> LSC XX.1.2 <br />EXIT REQUIREMENTS DEFINE SPACE. <br />10,000 SF MAX PATIENT TREATMENT <br />SUITE. 5,000 SF MAX PATIENT SLEEPING <br />SUITE. <br />SPACE REQUIRED TO LIMIT TRANSFER <br />OF SMOKE <br />EXIT PASSAGEWAY <br />SURROUNDING SYMBOLS INDICATE RATING <br />AND DAMPER REQUIREMENTS <br />(IBC 509.4, LSC XX.3.2) <br />Revised 12-12-2016 <br />SEE IBC 407.4.3