My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
04-07-21 Planning Commission
ArdenHills
>
Administration
>
Commissions, Committees, and Boards
>
Planning Commission
>
Planning Commission Packets
>
2021
>
04-07-21 Planning Commission
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/2/2021 2:30:25 PM
Creation date
4/2/2021 2:24:59 PM
Metadata
Fields
Template:
General
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
208
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
City of Arden Hills <br />Planning Commission Meeting for April 7, 2021 <br />P:\Planning\Planning Cases\2021\21-001 - BSC Bldg 14 Addition - APUD\PC Packets <br />Page 3 of 6 <br />C. Setbacks –Meets Requirements <br />Setbacks in the I-1 District are 50 feet for the front yard, 20 feet for the side yard with minimum <br />of 40 feet total for both side yards, and 20 feet for the rear yard. The proposed addition meets all <br />of the required setbacks. <br />2. Design Standards - Section 1325.05 and 1325.055 <br />A. Aesthetics – Meets Requirements <br />Exterior elevation plans submitted by the Applicant indicate that the proposed addition will <br />utilize precast panels and prefabricated metal panels complimentary in color and texture to the <br />existing building. As a condition of approval, staff recommends that The Applicant submit a <br />materials board to compare proposed materials against the existing buildings on campus. <br />B. Lighting – Meets Requirements <br />Architectural lighting strips are located in the south wall of the addition, and there is a wall <br />mounted light on the west side of the building. In addition, parking lot lighting on the south and <br />east side of the building is proposed. Given the minimal outdoor lighting for the project and the <br />distance from the adjacent residential areas, staff do not anticipate any issues with regard to <br />lighting. However, as a condition of approval staff recommends the Applicant be required to <br />provide photometric calculations for the lighting at the west property line. <br />C. Screening and Fencing –Meets Requirements <br />Screens and fencing help minimize adverse impacts of public nuisances, such as noise. According <br />to City Code Section 1325.05, subd. 4, mechanical equipment requires screening to be constructed <br />and located so as to completely screen them from view of adjacent streets and differing land uses. <br />In addition to the mechanical penthouse, the Applicant is proposing a parapet wall to screen rooftop <br />mechanical equipment. The height of this wall has been increased to meet the noise standards. <br />D. Tree Preservation –Meets Requirements <br />A Tree Preservation Plan is required as part of an application when City grading permit or erosion <br />control permit is required. The Tree Protection Plan submitted by the Applicant shows that 95 <br />caliper inches of significant trees are set for removal. The Ordinance allows 10% (36.2 caliper <br />inches) to be removed without replacement. The remaining 58.8 caliper inches to be removed must <br />be replaced at a ratio of 1 caliper inch for each 2 inches removed. The Applicant is required to <br />replant 29.4 caliper inches. The proposed landscaping plan identifies a total of 63.5 caliper inches <br />of replacement trees. The proposed replacement trees included a variety of deciduous and <br />evergreen trees. As a condition of approval, staff recommends a landscaping letter of credit or <br />escrow be required. <br />E. Parking, Traffic, and Circulation – Meets Requirements <br />The Applicant is proposing to provide an additional 10 parking spaces, and submitted Proof of <br />Parking calculations for an addition 88 spaces. The addition of 17,450 square feet of floor area <br />requires an additional 18 spaces. The new spaces plus proof of parking meets this requirement.
The URL can be used to link to this page
Your browser does not support the video tag.