Laserfiche WebLink
<br />____________________________________________________________________________________ <br />Page 13 of 17 <br /> <br /> <br />3. 1355.04 Procedural Requirements for Specific Applications <br />A public hearing for a PUD Amendment request is required before the request can be brought <br />before the City Council. The applicant or its representative shall be given the opportunity to appear <br />before the Planning Commission to answer questions or give explanations regarding the proposal. <br />Upon completion of the public hearing and its study and consideration of the application, the <br />Planning Commission shall submit its written report, containing its findings, conclusions, and <br />recommendations as to the application, to the City Council. <br /> <br />Plan Evaluation Summary <br /> <br />The table below provides the performance standards for the B-3 District and the preliminary <br />analysis for the proposed development: <br /> <br />Ordinance Requirements B-3 District Standards Proposed Development <br />Maximum Floor Area Ratio (FAR) 0.8 Approx. 0.23 <br />Maximum Building Height 35 feet +/- 29 feet <br />Maximum Structure Coverage 40% 23% <br />Minimum Landscape Lot Area 25% 15.0% <br />Minimum Front Yard Setback 50 feet Bank/Dental: 19.2 feet – Lexington <br />Avenue and +/- 138 feet Grey Fox <br />Road <br />Aldi: 74 feet – Grey Fox Road <br />Minimum Rear Yard Setback 20 feet Bank/Dental: 21.4 feet <br />Aldi: 30 feet <br />Minimum Side Yard Setback 20 feet (min)/ <br />40 feet (total) <br />Bank/Dental: +/- 62 feet (min) / <br />N/A corner lot (total) <br /> <br />Aldi: 120 feet (east) and 10 feet <br />(west) <br />Building Positioning At Front Setback = 50 feet Bank/Dental: 19.2 feet – Lexington <br />Avenue and +/- 138 feet Grey Fox <br />Road <br />Aldi: 74 feet – Grey Fox Road <br />Minimum Parking Requirements 120 total stalls 143 total stalls <br />Off-Street Parking Setbacks 20 feet from ROW 5 feet <br />Building Façade 50% transparency at front <50%, Varies between building <br />Building Materials 75% brick, tile, natural <br />stone, decorative concrete, <br />transparent glass or any <br />combination thereof <br />Seeking Flexibility to allow overall <br />building design versus calculating <br />per elevation. <br />Pedestrian and Bicycle Circulation 6 foot sidewalk None along Lexington Avenue – <br />Defers to project <br />5 foot – Grey Fox Road <br />Freestanding Sign Copy Area 100 square feet 110 square feet <br />Wall Signage Sign District 5 Complies with Sign District 5 <br /> <br />Additional Review <br /> <br />Building Official <br />The Building Official has reviewed the plans and has no additional comments at this time. A <br />Building Permit will be required prior to any construction taking place. <br />