Laserfiche WebLink
<br />Page 9 of 14 <br /> <br />PARKING <br />Based on Developer’s review and interpretation of City Zoning Code, the R4 Multiple Family District requires <br />the following minimum parking provisions: 1.1 per studio, 1.1 per 1-bedroom, 2 for 2-bedroom. The finalized <br />unit mix and parking count for this project has not been determined. The following is the current <br />approximate assumption. The Developer will update/finalize within the next submittal. <br /> <br /> Example, based on 120 Units % of Units # of Units City Req. Stalls Proposed <br /> 1 Bbd/ 1 Bbd + Den Proposed = 35-45% 42- 54 46.2 - 59.4 xx <br /> 2 Bbd/ 2 Bbd + Den Proposed = 55%-65% 66 - 78 132 - 156 xx <br /> 178.2 - 215.4 216 <br /> <br />The Developer does not believe a deviation to City Zoning Code for minimum parking stalls will be <br /> required. <br /> <br /> <br />VEHICLE ACCESS <br />Based on informal input obtained from two neighborhood meetings RE this proposed project—the developer <br />believes access should come from County Highway 96 exclusively—and no access to this proposed project <br />shall be allowed internally, through the existing North Heights Lutheran Church campus (to Snelling Avenue). <br />In an effort to accomplish said goal, the Developer has made the following adjustments to the proposed site <br />plan: <br /> <br />• The apartments parking lot, and the North Heights Lutheran Church parking lot, are now separated <br />by a physical barrier (raised boulevard with landscaping). <br />• Access to the apartments garage and apartments surface parking lot are located at furthest northern <br />possible location—against County Highway 96. <br />• Provisions of exiting restrictions have been added to both apartment exit points. The developer has <br />added: a left turn only arrow to be painted on the pavement, at both apartment exit points; a no <br />right turn sign has been added at both apartment exit points; concrete curbing will be bumped (as <br />much as allowed by City Engineer) to help force left only exits—and help physically restrict right-out <br />exits—at both apartment exit points. <br /> <br />Internal to the site, care will be placed in the design of the parking lot to allow for the flow and circulation of <br />both residents’ vehicles and larger vehicles; such as fire apparatus and delivery trucks; which allow delivery <br />trucks to safely and efficiently enter the site. The developer has included a 24’ wide internal circulation dive <br />lane for parking areas, and a 20’ wide fire department access road around the rear of the building—which <br />includes a turn-around provision. <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br />