My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
CCP 11-09-1992
ArdenHills
>
Administration
>
City Council
>
City Council Packets
>
1990-1999
>
1992
>
CCP 11-09-1992
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/8/2007 1:09:16 PM
Creation date
11/6/2006 2:40:39 PM
Metadata
Fields
Template:
General (2)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
87
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br /> . ' , <br /> DATE: November 4, 1992 <br /> FROM: Fire Marshal Mike Zustiak <br /> Assistant Fire Marshal Dan Winkel <br /> - . <br /> TO: Catherine Iago, Deputy Clerk/Zoning <br /> Administrator <br /> RE: Case # 92-17 - PUD, Cottage Villas of Arden Hills, <br /> Cleveland Avenue, John Arkell <br /> Fire Marshal Mike Zustiak and I have reviewed the most recent <br /> plans submitted for the "Cottage Villas of Arden Hills" <br /> development located on Cleveland Avenue, south of County Road <br /> E-2. There are a few issues related to fire safety that we would <br /> like to bring to the attention of the Planning Commission. The <br /> issues are as follows: <br /> l- During the plan review, neither the Fire Marshal nor I <br /> could identify a fire suppression sprinkler system for <br /> the entire complex. It is the opinion of the Lake <br /> . Johanna Fire Department that the entire complex should <br /> be sprinkled. <br /> 2. The proposed fire hydrant location does not appear to <br /> be adequate for fire department equipment use. It is <br /> requested that an additional hydrant be installed and <br /> the location of both hydrants be discussed with the <br /> Fire Marshal. <br /> 3. The Fire Department is concerned that there is no <br /> access to the rear portion of the proposed buildings <br /> for fire equipment. It is requested that a 10-ton <br /> access road, twenty (20) feet wide, be constructed <br /> around the entire complex. This type of fire access <br /> road has previously been requested and constructed when <br /> development projects have had limited or no access for <br /> fire equipment on the rear portion of the building. <br /> Thank you for your consideration of the above listed items. <br /> . <br />
The URL can be used to link to this page
Your browser does not support the video tag.