<br /> 1/..-:/ <br /> I Lift Stntion Number I <br /> I- Location: Arden Hills Trail <br /> Type: Wet well! Dry well <br /> Manufacturer: Smith & Loveless <br /> I Construction: Concrete wet well, Steel tube dry well <br /> Design Capacity: 200 gpm at 31 feet TDH <br /> . Constructed: 1959, modifications - cover was replaced and access tube extended with <br /> grading changes for parking area; 1993 New electrical service was <br /> installed; no major pump' or motor modifications. <br /> . Co=ents: <br /> The dry well tube and cover were modified when the adjacent to\Nll house units were <br /> I constructed and the replacement cover is somewhat distorted and corroded, <br /> In 1993 the electrical service was replaced by i\id Electric, and the overall station was <br /> checked out but there was no work done on the controls. <br /> . According to operating personnel the station is relatively trouble free except for routine <br /> maintenance. During wet weather conditions, there is an increase in the pump running times <br /> indicating some infiltration/inflow in the service area of this lift station. <br /> . Preliminary Reco=endations: <br /> .e The wet well cover needs replacement or at least some repair and recoating for corrosion <br /> protection. The dry well tube and floor should also be inspected and possibly spot cleaned and <br /> recoated as necessary. <br /> I Lift Stntion Number 2 <br /> I Location: Easement west of Chatham Avenue <br /> Type: Wet weW Dry well <br /> . Manufacturer: Custom Built, PACO Pumps <br /> Construction: Concrete wet well and dry well inside building <br /> Design Capacity: 900 gpm at is ft TDH (one pump); 1100 gpm at 89 ft IDH (two pumps) <br /> I Constructed: 1977, major upgrade in 1983 <br /> Co=ents: <br /> . The 1983 upgrade work included the installation oflong shafts on the pumps with <br /> relocation of the drive motors to a ground level concrete slab, and construction of a small building <br /> . over the wet well and dry' well and replacement of the pump controls. <br /> This station was not viewed, however according to operating personnel, the construction <br /> is similar to the building at stations 5 and 8. In these locations, the wet well is under the building <br /> ~ ~ <br /> . and access is prov~ded in a separate room with a separate access door from the outside, Electrical <br /> controls and the pump motors are located in an adjacent room with separated access to the <br /> outside. There are safety concerns on the wet well side due to the confu1ed space classification of <br /> .e this type of design, The dry well side prov~des good access to the pumps and mOlOrsfor <br /> . <br />