Laserfiche WebLink
<br />Page 13 of 24 <br /> <br />Rendering of South and North Elevations – Event Center <br /> <br /> <br />Section 1325.05, Subd. 8, F. states that fifty percent (50%) of all first level building façades that <br />front a public street shall be comprised of transparent windows or doors in order to allow views of <br />interior uses and activities. If the building is a one story design and the first floor elevation exceeds <br />12 feet, then only the first 12 feet shall be included in calculating the façade area. <br /> <br />The south and east elevations of the existing building have some frontage on Connelly Avenue. <br />The Applicant is seeking flexibility from the transparency standard due to the construction of the <br />existing building and the nature of the proposed use. The east elevation of the building is <br />constructed of concrete block with existing covered openings near the roofline. It would be <br />difficult to add a significant number of windows into the existing concrete block walls to meet the <br />50% requirement. The Applicant also states that the function of an event space requires a certain <br />level of privacy and that windows viewing the activity inside the space would not be conducive to <br />the activity. <br /> <br />The Applicant offers that the existing main entrance at the southeast corner of the building consists <br />of glass windows and glass entry doors with additional windows on the south wall. The proposal <br />includes plans to maintain the main entry to allow views of the activities in the restaurant and bar <br />areas of the building. The proposal would still enhance the existing building’s appearance while <br />serving the functions inside. <br /> <br />B. Building Positioning – Nonconforming <br />Section 1325.05 Subd. 8, E of the Arden Hills City Code states “at least fifty percent (50%) of the <br />largest building on each site shall be constructed at the front setback line.” The minimum front <br />yard setback for the B-2 District is 50 feet and the existing front setback line is at 48.8 feet, which <br />encroaches into the minimum setback. The Applicant is not proposing changes to the existing <br />setback and would maintain the existing setback with the proposed development. <br /> <br />C. Lighting – Flexibility Requested <br />The Zoning Code requires exterior lighting to be consistent in type, design, scale, and color to <br />create unity in the Districts. Exterior lighting for parking lots and buildings shall not be <br />excessive and shall be directed at their intended purposes. Any light or combination of lights <br />shall not cast light that exceeds a meter reading of one foot candle on the travel lanes of <br />adjoining public streets or 0.4 foot candles on adjoining residential property. <br />