Laserfiche WebLink
<br /> , <br /> , <br /> 6A. Sign age - Clarification needed On wall signage, clarification needed on freestanding sign <br /> lighting; meets all other sign requirements. . <br /> The plans do not indicate locations of signage for the property. Sign age for the property as <br /> permitted by the Sign Ordinance would include the following: <br /> Sign age <br /> Type of Sign Sign District 8 Regulations Proposed <br /> Wall Silmal!e Max Area 30 sf *#30 sf <br /> Max Height 14 ft - <br /> Lightinl! Not permitted #ExternallUnspecified <br /> Freestanding Signage Max Area 60 sf **50 sf <br /> Max Height 8ft 6ft <br /> (sign and support) <br /> Lighting ExtemaVIntemal ***InternaIlBacklit? <br /> Auxiliarv Sign age Wall 6 sf Insufficient data <br /> Freestanding 6 sf Insufficient data <br /> Max Height Wall 6ft 1-2 ft <br /> (of Sign Face) <br /> Freestandinl! 6ft 3,5 ft <br /> * Sectiou 333.9 of the Sign Ordinance: "In multi-tenant buildings or sites the permitted sign area and sign types, <br /> except for permitted freestanding signs, may be installed by each individual business establishment that has <br /> exclusive use of some portion of the street or otherwise primary level of the building and direct access to the <br /> outside. .. - All 30 units conld have 30 sf of unlit wall signage. . <br /> "The applicant's letter states that they are requesting a sign of ]20 square feet which is the total sign mass. The 50 <br /> square feet shown above is the area of the sign face, which is what this provision regulates_ <br /> ***The plans show PIN mounted letters on a metal panel. The assumption is that these are illuminated channel <br /> letters which would be permitted. The sign ordinance does not allow the face of the sign to he backlit in this sign <br /> district. <br /> #The application is confusing in that it shows Ihe "Typical Address Sign and Light" (sheet A2.2) and also include <br /> areas on Ihe walls for "Optional Siguage" (on both sheets A2.] and A2.2). It appears that every unit would have the <br /> externally illuminate "Address Sign and Light" and unit owners could purchase the "Optional Signage." While it <br /> appears that a unit owner could have both signs and still meet our sign size criteria (total would be about 21 sf), the <br /> tolal amount of signage on the building could be 126 sf (on the 6 unit building). Staff recommends a condition in <br /> the POO document establishing a comprehensive sign plan for the development (as part of or an addendum to the <br /> PUD document) which would place restrictions on the location and design of signage. <br /> 7A. AestheticslBuilding Materials ~ Main building material meets requirement, <br /> secondary/trim materials are not included as permitted exterior materials, <br /> The site layout includes four buildings with 1 and 2-story units slab on grade, The remaining 3 <br /> buildings would be 1 and 2-story walkouts. The overall design offhe buildings is supposed to <br /> give the impression of a residential townhouse development. Dormers are used above the 1- <br /> story units to give the impression of a second floor. The 2-story units include fhe gables where <br /> actual windows would bring light into the office condominiums. <br /> \\Earth\Planning\Planning Cases\2005\05-12 Arden Hills Office Park - Royal Oaks Realty - PUD, PrcliminalY Plat for Old City Hall & PW Site . <br /> (PENDING)\06-01-04 PC Report Royal Oaks 05-12.doc <br /> Page 8 of 18 <br /> -------- <br />