My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
CCP 01-13-2003
ArdenHills
>
Administration
>
City Council
>
City Council Packets
>
2000-2009
>
2003
>
CCP 01-13-2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/8/2007 1:18:06 PM
Creation date
11/14/2006 2:33:51 PM
Metadata
Fields
Template:
General (2)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
100
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />,_ t_, <br /> <br />DBC 1 & 2. Systems are designed to deliver primary outside air to the Fan Powered Variable Volume <br />Boxes at controlled temperature and dew point. Multiple heat recovery systems associated with units are <br />designed to use the building's exhaust air as a heating and cooling source for the incoming outside air <br />required for building ventilation. Field Installation Verification and Operational Perfonnance Reports have <br />been completed and deficiencies noted. <br /> <br />Functional Performance Testing has commenced. Commissioning Team recommended control sequence <br />changes and engineer and manufacturer are in the process of developing new sequences to meet design <br />criteria. Remaining Functional Testing will be accomplished when new seqnences are implemented. <br /> <br />A Performance Curve will be generated once new sequences are installed. <br /> <br />Fan Powered V A V Boxes. Systems are designed to deliver a mixture of required outside air and return air <br />at the required temperature and dew point to maintain desired temperature in each classroom. Systems have <br />been tested and balanced. Balancing of 20% of the boxes has been verified and accepted by the <br />Commissioning Team. <br /> <br />Each room is equipped with an occupancy sensor which indexes the Fan Powered Box from unoccupied to <br />occupied. In unoccupied mode the primary air is reduced and the room temperature is reset to save energy. <br /> <br />Field Installation Verification Testing has been completed. <br /> <br />Functional Performance Testing has been completed and verified. <br /> <br />BAS Svstem. Building Automation System is fully operational, with critical alarm dialing to District's <br />service provider. All system sequences have been verified. Temperature and humidity sensors were <br />verified for calibration. Valves and damper actuators were also verified. Systems graphics have installed <br />and verified. <br /> <br />Humidiry sensors are critical to the operation of the system. They should be checked on a routine basis for <br />accuracy. We recommend each school have at least one cahbrated sensor on hand for replacement <br />purposes. <br /> <br />A complete list of deficiencies has been generated and passed to control contractor for action. <br /> <br />7 <br /> <br />. <br /> <br />. <br /> <br />. <br />
The URL can be used to link to this page
Your browser does not support the video tag.