Laserfiche WebLink
<br /> 2. II is designed to internally flood and is constructed with tluod rl."sistant <br /> materials; and <br />. 3. It is used solely for parking of vehicles. building aecess or storage. <br /> B. The above-noted alternative elevation methods shall be subjeclto the follllwing <br /> additional standards: <br /> J. Design and Certification. The structure's design and as-built condition <br /> shall be certified by a rcgistered professional engineer or architect as being <br /> in comp)iance with the gencral design standards of the State Building <br /> Code and, specifically. that all electrical, heating. ventilation. plumbing <br /> and air conditioning cquipment and other service facilities shall be at or <br /> above the Regulatory Flood Protection Elevation or be designed to prcvent <br /> flood water from entcring or accumulating within thcse compunents <br /> during ti mes of flooding. <br /> 2. Specific Standards for Above-Grade. I:nclosed Areas. Above grade. fully <br /> enclosed arcas such as crawl spaces or tuck under garages shall be <br /> designcd to intcrnally flood and thc design plans shall stipulate: <br /> a. The minimum area of openings in the walls where intcrnal lIooding is <br /> to be lIsed as a flood proofing technique. When openings <Ire rlaCl~d in <br /> a structure's walls to providc for entry of flood waters 10 equalizc <br /> pressures, thc bottom of all openings shall he no higher than one foot <br /> above gradc. Openings may bc equipped with screens. louvers. valves. <br /> or othl'r coverings or devil~es provided that they permit the automatic <br /> entry and exit of flood waters. <br /> b. That the enclosed area shall be designed of Ilood resistant materials in <br /> accordance with the FP-3 or 1'1'-4 classifications in the State Building <br />. Codc and shall be used solely for building aecess, parking of vehicles <br /> or storage. <br /> C. Basements. as defined by this Section. shall be subject to the following: <br /> J. Residential basemcnt construction shall not be allowed below thl' <br /> Regulatory Flood Protection E1cvation. <br /> 2. Non-residential basements may be allowed below the Regulatory Flood <br /> Protection Elevation provided the basement is structurally dry flood <br /> proofed in accordance with this Section. <br /> D. All areas of non-residential struetures including basements to be placed below <br /> the Regulatory Flood Protection Elevation shall be flood proofed in accordance <br /> with the structurally dry 1100d proofing classifications in the St<lte Building <br /> Code. Structurally dry flood proofing shall meet the FP- J or FP-2 flood <br /> proofing classification in the State Building Code and this shall require making <br /> the structure watertight with the walls substantially impermeable to the passage <br /> Se~lion 1335 Flood Plains <br /> I'age 7 of 19 <br />. <br />