<br />The above structure and impervious coverage chart has been revised to include the total land <br />area, the total water area, and the proposed lot coverage of the land area for each City. <br />Please note that the impervious coverage includes the structure coverage. TKDA did indicate <br />that the proposed building and overall impervious coverage is estimated since the actual <br />footprint of a structure may change when the College moves forward with a particular <br />construction project. As noted above, all construction projects in Arden Hills are subject to <br />the site plan review process, which requires Planning Commission and City Council review. <br /> <br />The additional buildings would not cause the campus to exceed the twenty-five (25) percent <br />structure coverage limit in Arden Hills; however, the campus may slightly exceed the thirty- <br />five (35) percent overall impervious coverage limit by about one percentage point on the <br />Arden Hills side of the campus. However, when viewing the entire campus, the total <br />impervious coverage would be only thirty-four (34) percent. Since the Roseville portion of <br />the Campus is within a different zoning classification, the impervious and structure coverage <br />limit may vary in Roseville depending on the type of development. <br /> <br />The City can permit the campus to exceed the thirty-five (35) percent impervious coverage <br />limit as part of the PUD approval process. However, a condition limiting the campus to <br />thirty-five (35) percent coverage could be included and, if necessary, the College could <br />approach the City in the future with a PUD amendment to increase the coverage limit if <br />deemed necessary. It is also possible that the thirty-five (35) percent limit will not be <br />exceeded since the exact impervious/building coverage will not be fully determined until a <br />particularly structure is designed. <br /> <br />2. Lot and Lake Setbacks <br /> <br />While the Master Plan meets the minimum side setbacks required in the R-I Zone, the PUD <br />process can allow the City to require a greater setback to reduce any potential impacts on <br />adjacent properties. It may be prudent to discuss setting greater minimum building setbacks <br />to decrease the impact of the College on adjacent properties, particularly along the eastern <br />property line. The City ofRoseville is moving forward with a 75 foot setback along the <br />eastern property line and a 30 foot setback along the western property line. Staff has <br />included a similar requirement in the conditions of approval to maintain consistency and to <br />reduce the potential impact on adjacent properties. <br /> <br />The PUD report indicates that Little Lake Johanna is classified as a General Development <br />(GD) lake in Arden Hills and a Recreational Development (RD) lake in Roseville. The lake <br />designation is set by the Minnesota Department of Natural Resources, and Little Lake <br />Johanna is an RD lake. An RD lake requires a minimum 75 foot setback from the ordinary <br />high water mark despite what is stated in the Arden Hills Zoning Code. The Zoning Code <br />needs to be updated to reflect this requirement set by the DNR. <br /> <br />City of Arden Hills <br />Planning Commission Meetingfor October 3, 2007 <br /> <br />\\Metro-inet.us\ardenhills\Planning\Planning Cases\2006\06~037 Northwestern College Master Plan (PENDING)\100307 - PC Report- <br />Northwestern College Master Plan.doc <br /> <br />Page 5 of 12 <br />