My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Res. #15-036 - Approving Plans & Specs. & Ordering Ad. For Bids
Centerville
>
City Council
>
Resolutions
>
2000-2024
>
2015
>
Res. #15-036 - Approving Plans & Specs. & Ordering Ad. For Bids
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/10/2015 9:10:24 AM
Creation date
11/10/2015 9:47:22 AM
Metadata
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
225
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
City of Centerville <br /> Project SP-07-03738 <br /> November 29,2007 <br /> Page 10 <br /> We recommend that material selected for granular subbase conform to Mn/DOT Specification 3149.2B2 <br /> for Select Granular Borrow,sand having no more than 12 percent of the particles by weight passing the <br /> ##200 sieve <br /> D.3. Placement and Compaction of Backfill and Fill <br /> We recommend spreading backfill and fill in 4-to 8-inch lifts,depending on the composition of the <br /> material and the type of compactor(s)used. The relative compaction of the backfill and fill should meet <br /> or exceed the recommended values presented below in Table 4. The recommended values are <br /> percentages of the materials' standard Proctor dry density(ASTM D 698). <br /> Table 4. Compaction Recommendations Summary <br /> Moisture Content Variance from Optimum, <br /> percentage points <br /> Relative Compaction, <br /> percent Soil containing no Soil containing more <br /> (ASTM D 698— more than 12 percent than 12 percent <br /> Reference standard Proctor) passing the#200 sieve passing the#200 sieve <br /> Below pavements,within 3 feet <br /> of subgrade elevations 100 -3 to+3 -1 to+3 <br /> Below pavements,more than 3 <br /> feet below subgrade elevations 95 -3 to+3 -I to+3 <br /> Below landscaped surfaces 90 NA NA <br /> D.4. Pavements <br /> DA.a. Subgrade Proofroll <br /> After the subgrade has been prepared as previously recommended,we recommend test-rolling it to check <br /> for localized soft areas,. Loose,soft or unstable areas observed will require additional stabilization, <br /> compaction and/or subexcavation of those materials. We recommend that the gest-rolling procedure be <br /> observed by a geotechnical engineer to assist in evaluating the suitability of'the pavement subgrade. A <br /> proofroll should be performed just prior to placement of the geotextile and again just prior to placement <br /> of the pavement. <br /> DA.b. Geotextile <br /> We recommend installing geotextile in accordance with Mn/DOT Specification 3733B Type V- <br />
The URL can be used to link to this page
Your browser does not support the video tag.