Laserfiche WebLink
<br />e <br /> <br />Chapter 24 <br /> <br />TENTS AND OTHER MEMBRANE STRUCTURES <br /> <br />SECTION 2401 <br />GENERAL <br /> <br />2401.1 Scope. Temporary tents, canopies. air-supported, air- <br />inflated or tensioned membrane structures shall comply with <br />this chapter. The provisions of Sections 2401.2 through <br />2401.7.1, and Sections 2403, 2404,2405,2409 and 2410 are <br />applicable only to temporary membrane structures. All other <br />provisions are applicabl.e to temporary and permanent mem- <br />brane structures. <br /> <br />2401.2 Approval requlred. Tents and membrane structures <br />having an arellinexcess of2oo square feet (19 m') and canopies <br />in excess of 400 square feet (37 m') shall not be erected, oper- <br />ated or maintained for any purpose without first obtaining a <br />permit and approval from the code official. <br /> <br />Exceptions: <br />1. Tents used exclusively for recreational camping pur-' <br />poses. . <br />, 2. Fabric canopies and awnings open on all sides which <br />comply with all of the following: <br />2.1. Individnal canopies having a maximum size <br />of 700 square feet (65 m'). <br />2.2. The aggregate area of multiple canopies <br />placed side by side without a fire break clear- <br />ance of 12 feet (3658 rom) not exceeding 700 <br />square feet (65 m') tQtal. . <br />2.3. A minimum clearance of 12 feet (3658 rom) to <br />all structures and other tents. . <br />2401.3 Place of assembly. For the purposes of this chapter, a <br />place of assembly shall include a circus, carnival, tent show, <br />theater, skating rink, dance hall or other place of assembly in or <br />under which persons gather for any purpose. <br />2401.4 Permits. Permits shall be required as set forth in Sec- <br />tion 105.7. <br /> <br />2401.5 Use period. Temporary tents, air-supported, air-in- <br />flated or tensioned membrane structures and canopies shall be <br />used for a period of not more than 180 days within a 12-month <br />period on a single premise. <br /> <br />2401.6 Construction docnrnents. A detailed site and floor <br />plan for tents, canopies, air-supported, aircinflated or tensioned <br />membrane structures with an occupant load of 50 or more shall <br />be provided with each application for approval. The tent, air- <br />supported, air-inflated, tensioned membrane structure or can- <br />.opy floor plan shall indicate details of the means of egress facil- <br />ities, seating capacity, arrangement of the seating and location <br />and type of heating and electrical equipment. <br /> <br />2401.7.Inspections. The entire tent, air-supported, air-inflated <br />or tensioned membrane structure system shall be inspected at <br /> <br />2000 INTERNATIONAL FIRE CODEiIIl <br /> <br />l <br /> <br />regular intervals, but not less than two times per permit use <br />period, by the permittee, owner or agent to determine that the <br />installation is maintained in accordance with NFP A 102. <br /> <br />Exception: Permit use periods of less than 30 days. <br /> <br />2401.7.1 Inspection report. When required by the code of- <br />ficial, an inspection report shall be provided and shall con- <br />sist of maintenance, anchors and fabric inspections. <br /> <br />SECTION 2402 <br />DEFINITIONS <br /> <br />2402,1 Defiultlons. The following words and terms shall, for <br />the purposes of this chapter and as used elsewhere in this code, <br />. have the meanings shown herein. . <br /> <br />AIR-SUPPORTED STRUCTURE; A strUcture wherein the <br />shape of the structure.!.s attained by air pressure, and occupants <br />of the structure are within the elevated pressure area. <br /> <br />CANOPY. A structure, enclosure or shelter constructed of fab- <br />ric or pliable materials supported by any manner, except by air <br />or the contents it protects, and is open without sidewalls or <br />drops on 75 percent or more of the perimeter. <br /> <br />TENT. A structure, enclosure or shelter constructed of fabric <br />or pliable material supported by any manner except by air or the <br />contents that it protects. <br /> <br />SECTION 2403 <br />ACCESS, LOCATION AND PARKING <br /> <br />2403.1 Access. Fire apparatus access roads shall be provided in <br />. accordance with Section 503. <br /> <br />2403.2 Location. Temporary membrane structures, tents, can- <br />opies, air-supported, or air-inflated structures shall not be lo- <br />cated within 20 feet (6096 rom) of lot lines, buildings, other <br />temporary membrane structures, other tents and canopies, <br />parked vehicles or internal combustion engines. For the pur- <br />pose of determining required distances, support ropes and guy <br />wires shall be considered as part of the temporary membrane <br />structure, tent or canopy. <br /> <br />Exceptions: <br /> <br />1. Separation distance between temporary membrane <br />structures, tents and canopies, not used for cooking, is <br />not required when the aggregate floor area does not <br />exceed 15,000 square feet (1394 m'). <br /> <br />205 <br />