<br />2403.3 - 2406.4 <br /> <br />2. Temporary membrane structures, tents or canopies <br />need not be separated from buildings when all of the <br />following conditions are met: <br />2.1. The aggregate floor area of the temporary <br />membrane structure, tent or canopy shall not <br />exceed 10,000 square feet (929 m'). <br />2.2. The aggregate floor area of the building and <br />temporary membrane structure, tent or can- <br />opy shall not exceed the allowable floor area <br />including increases as indicated in the Inter- <br />. national Building Code. <br />2.3. Required means of egress provisions are pro- <br />vi~d for both the building and the temporary <br />membrane structure, tent or canopy, including <br />travel distance. <br />.2.4. Fire apparatus access roads areprovil:ledinac- <br />. cordance with Section 503. <br />\ .' . <br />2403.3 Location of structuredn excess of 15,000 square feet <br />in area. Tents, air-supported. air-inflated or tensioned mem- <br />brane structures having an area of 15,000 square feet (1394 m2) <br />orinore shall be located not less than 50 feet (IS 240 rom) from <br />any other tent or structure as measured from the side wall of the <br />tent unless joined together by a canidor. <br />2403:.4 Connecting corridors. Tents, air-supported, air-in- <br />flated or tensioned membrane structures are allowed to be <br />joined together by means of corridors. Exit doors shall be pro- <br />vided at each end of snch corridor. On each side of such corri- <br />dor and approximately opposite each other, there shall be <br />provided openings not less than 12 feet (3658 inm) wide. <br /> <br />2403.5 Fire hreak. An unobstructed fire break passageway or <br />fire road not less than 12 feet (3658 rom) wide and free from <br />guy ropes or other obstructions shall be maintained on all sides <br />of all tents, air supported, air-inflated or tensioned membrane <br />structures unless otherwise approved by the code official. <br /> <br />SECTION 2404 <br />STRUCTURAL STABILITY <br /> <br />2404.1 Anchorage required. Tents, air-supported, air-inflated <br />or tensioned membrane structures and their appurtenances <br />shall be adequately roped, braced and anchored to withstand <br />the elements of weather and prevent against collapsing. Docu- <br />mentation of structural stability shall be furnished to the code <br />official on request. <br /> <br />SECTION 2405 <br />AIR-SUPPORTED AND AIR-INFLATED <br />STRUCTURES <br /> <br />2405.1 Door operation. During high winds exceeding 50 <br />miles per hour (80 kph) or in snow conditions, the use of doors <br />in air-supported structures shall be controlled to avoid exces- <br />sive air loss. Doors shall not lie left open. <br /> <br />2405.2 Fabric envelope design and construction. Air-sup- <br />ported and air-inflated structures shall have the design and con- <br />struclion of the fabric envelope and the method of anchoring in <br />accordance with Arcbitectural Fabric Structures Institute ASI 77. <br /> <br />2405.3 Blowers, An air-supported structure used as a place of <br />assembly shall.be furnished with not less than two blowers, <br /> <br />206 <br /> <br />TENTS AND OTHER MEMBRANE STRUCTURES <br /> <br />p <br /> <br />each of which has adequate capacity to maintain full inflation <br />pressure with normal leakage. The design of the blower shall be <br />so as to provide integral limiting pressure at the design pressure <br />specified by the manufacturer. <br /> <br />2405.4 Auxiliary power. Places of public assembly for more <br />than 200 persons shall be furnished with either a fully auto- <br />matic auxiliary engine-generator set capable of powering one <br />blower continuously for 4 hours, or a supplementary blower <br />powered by an internal combustion engine which shall be auto- <br />matic in operation. <br /> <br />. <br /> <br />SECTION 2406 <br />FIRE SAFETY REQUIREMENTS <br /> <br />2406.1 Flame.resistant treatment. Before a permit is granted, <br />the owner or agent shall me with the code official a certificate <br />executed by an approved testing laboratory, certifying that the <br />tents, air-supported, air-inflated or tensioned membrane struc- <br />turis and their appurtenances, sidewalls, drops and tops oftem- <br />porary membrane stru~tures, canopies, tarpaulins, floor <br />coverings, bunting, combustible decorative materials and ef- <br />fects, including sawdust when used on floors or passageways, <br />shall be composed of flame-resistant material or shall be <br />treated with a flame retardant in an approved manner and meet <br />the requirements for flame resistance as determined in accor- <br />dance with NFPA 701, and that sJlch flame resistance is effec- <br />tive for the period specified by the permit. <br /> <br />2406.1. Label. Temporary membrane structures, tents or cano- <br />pies shall haVe a permanently affixed label bearing the identifi- <br />cation of size and fabric or material type. <br /> <br />2406.3 Certification. An affidavit or affirmation shall be sub- <br />mitted to the code official and a copy retained on the premises <br />on which the tent or air-supported structure is located. The affi- <br />davit Shall attest to the following information relative to the <br />flame resistance of the fabric. <br /> <br />1. Names and address of the owners of the tent or air-sup- <br />ported structure. <br /> <br />2. Date the fabric was last treated with flame-resistant soln- <br />tion. <br /> <br />3. Trade name or kind of chemical used in treatment. <br /> <br />4. Name of person or firm treating the material. . <br /> <br />5. Name of testing agency and test standard by which the. <br />fabric was tested. <br /> <br />2406A Combustible materiaIs. Hay, straw, shavings or simi- <br />lar combustible materials shall not be located within any tent or <br />air-supported structure containing an assembly occupancy, ex- <br />cept the materials necessary for the daily feeding and care of <br />animals. Sawdust and shavings utilized for a public perfor- <br />mance or exhibit shall not be prohibited provided the sawdust <br />and shavings are kept damp. Combustible materials shall not be <br />permiited under stands or seats at any time. The areas within <br />and adjacent to the tent or air-supported structure, shall be <br />maintained cIearof all combustible materials or vegetation that <br />could create a fire hazard within 20 feet (6096 rom) from the <br />structure. Combustible trash shall be removed at least once a <br />day from the structure during the period the structure is occu- <br />pied by the public. <br /> <br />2000 INTERNATIONAL FIRE CODE@ <br />