<br />. <br /> <br />2410.5.1 - 2413.3 <br /> <br />. <br /> <br />. 2410.S.1 Arrangement and maintenance. The arrange- <br />ment of aisles shall be subject to approval by the code offi- <br />cial and shall be maintained clear at all times during <br />occupancy. <br /> <br />2410.6 Exit sigus. Exits shall be clearly marked. Exit signs <br />shall be installec1 at required exit dootways and where other- <br />wise necessary to indicate clearly the direction of egress when <br />the exit serves an occupant load of 50 or more. <br /> <br />2410.6.1 Exit sign illumination. Exit signs shall be of an <br />approved self-luminous type or shall be internally or exter- <br />nally illuminated by fixtures supplied in the following man- <br />. ner: <br /> <br />1. Two separate circuits, one of which shall be separate <br />from all other circuits, for occupant loads of 300 or <br />less; or .' . <br /> <br />2. 'Iylo separate sources of power, one of which shall be <br />an approved emergency system, sball be provided <br />I <br />when the occupant load exceeds 300. Emergency sys- <br />tems shall be supplied from storage batteries or the <br />on-site generator set. and the system shall be installed <br />in accordance with the ICC Electrical Code. <br /> <br />2410.7 Means of egress illumination. Means of egress shall . <br />be illuminated with light having an intensity of not less than 1 <br />foot-candle (11 lux) at floor level while the stmcture is occu- <br />pied. FIXtures required for means of egress illumination shall <br />be supplied from a separate circuit or source of power. <br /> <br />~10.l! Maintenance of means ofegress. The required width <br />~f exits, aisles aild passageways shall be maintained at all times <br />to a puhlic way. Guy wires, gny ropes and other support mem- <br />ben shall not cross a means of egress at a height ofless than 8 <br />feet (2438 rom). The surface of means of egress shall be main- <br />tained in an approved manner. <br /> <br />SECTION 2411 <br />HEATING AND COOKING EQUIPMENT <br /> <br />2411.1 Installation. Heating. or cooking equipment, tanks, <br />piping, hoses, fittings, valves, tubing and other related compo- <br />nents shall be installed as specified in the International Me- <br />cluinical Code and the International Fuel Gas Code, and shall <br />be approved hy the code official. . <br /> <br />2411.2 Venting. Gas, liquid and solid fuel-burning equipment <br />designed to be vented shall be vented to the outside JIir as speci- <br />fied in the International Fuel Gas Code and .the International <br />Mechanical Code. Such vents shall be equipped with approved <br />spark arresters when required. Where vents or flues are used, <br />all portions of the tent, JIir-suppOrted, JIir-inflated or tensioned <br />membrane stmctures, temporary membrane stmctures or cano- <br />pies shall be not less than 12 inches (305 mm) from the flue or <br />vent. <br /> <br />2411.3 Location. Cooking and heating equipment shall not be <br />located within 10 feet (3048 rom) of exits or combustible mate- <br />rials. . <br /> <br />~11.4 Operations, Operations such as warming of foods, <br />cooking demol1strations and similar operations that use solid <br />flammables, butane Or other similar devices which do not pose <br />an ignition hazard, shall be approved. <br /> <br />208 <br /> <br />TENTS AND OTHER MEMBRANE STRUCTURES <br /> <br />2411.S Cooking tents. Tents where cooking is performed shall <br />be separated from other tentS, air-supported, air-inflated or <br />tensioned membrane stmctures. temporary membrane stmc- <br />tures or canopies by a minimum of 20 feet (6096 rom). <br /> <br />2411.6 Outdoor cooking. Outdoor cooking that produces <br />sparks or grease-Iadeu vapors shall not be performed within 20 <br />feet (6096 mm) from a tent, air-supported, air-inflated or <br />tensioned membrane structure, temporary membrane structure <br />or canopy. <br /> <br />2411.7 Electrical heating and cooking equipment. Electrical <br />cooking and heating equipment shall comply with the ICC <br />Electrical Code. <br /> <br />SECTION 2412 <br />lP.GAS <br /> <br />2412.1 General. LP-gas equipment such .as tanks, piping, <br />hoses, fittings, valves, tubing and other .related components <br />shall be approved and'in accordance with the International <br />Fuel Gas Code and Chilpter 38. <br /> <br />2412.2 Location of containers. LP-gascontainers shall be lo- <br />cated outside. Safety rel~asevalves shall be pointed away from <br />the tent; JIir-supported, air-inflated or tensioned membrane <br />structure,orcanop~ . <br /> <br />2412.2.1 Containers SOO gallons or less. Portable LP-gas <br />containers of 500 gallons (1893 L) or less capacity shall <br />have a minimum separation between the container and <br />stmcture not less than 10 feet (3048 rom). <br /> <br />2412.2.2 Containers more than 500 gallons. Portable LP- <br />gas containers of more than 500 gallons (1893 L) capacity <br />and shall have a minimum separation between the container <br />and stmctures not less than 25 feet (7620 mm). <br /> <br />2412.3 Protection and security. Portable LP-gas containers, <br />piping, valves and fittings which are located outside and are be- <br />. ing used to fuel equipment inside a tent, air-supported, JIir;in- <br />flated or tensioned membraile structure, temporary membrane <br />stmcture or canopy sball be adequately protected to prevent <br />tampering, damage by vehicles or other hazards and shalll>e lo- <br />cated in an approved location. Portable LP-gas containers shall <br />be securely fastened in place to prevent unauthorized move- <br />ment. <br /> <br />SECTION 2413 <br />FLAMMABLE AND COMBUSTIBLE LIQUIDS <br /> <br />2413.1 Use. Flammable-liquid-fueled equipment shall not be <br />used in tents, air-supported, air-inflated or tensioned mem- <br />brane structures, temporary membrane stmctures Or canopies. <br /> <br />2413.2 F1ammable and combustible liquid storage. Flam- <br />mable and combustible liquids shall be stored outside in an ap- <br />proved manner not less than 50 feet (15 240 mm) from tents, <br />JIir-supported, air-inflated or tensioned membrane structures, <br />temporary membrane structures or canopies. Storage shall be <br />in accordance with Chapter 34. . <br /> <br />2413.3 Refueling. Refueling shall be performed in an ap- <br />proved location not less than 20 feet (6096 mm) from tents, air- <br /> <br />2000 INTERNATIONAL FIRE CDDE@ <br />