Laserfiche WebLink
It <br />• landscaping plan - a plan showing. 9 trees and 18 shrubs has been. submitted.. <br />Four of the trees are proposed to be pine. Approximately 1 C' shrubs are. <br />proposed within the Sch'euneman Road right-of-way. Staff has asked the <br />applicant to provide two additional trees; as required by the landscaping <br />section of the. Consolidated Land Use Ordinance. <br />In addition, the. building must be designed by a registered architect and <br />plans signed by a P.E. <br />it must be noted that the building exterior is proposed to be corrugated metal siding... <br />Corrugated siding is not permitted in. the Gateway Zoning District. - Polar is <br />requesting a variance from this requirement. They have added a 3' brick Wainscoting <br />to the front of the building. <br />Other ordinance.requirements, which must be addressed by the: applicant, include: <br />• 25% of the land must be landscaped by grass, shrubbery or trees - an updated <br />landscaping plan has been provided. <br />• one 180 square foot minimum landscaped island must be provided in the <br />parking lot does the updated plan meet thisrequirement? <br />• the following landscaping must be provided based on. the site perimeter: <br />- 11 trees 30% of which must be conifers 9 trees are proposed., 4 of <br />which are.. proposed to be.pine. <br />18 shrubs, a minimum of 36"tali - 18 shrubs are now proposed <br />the landscaped area must be irrigated - an irrigation detail is not shown on the <br />landscaping plane- there are no plans to extend sewer and water to the building. <br />No irrigation is planned for the landscaped areas. The. applicant is requesting <br />a variance from this ordinance requirement. A variance from Section 26,4.6. <br />must be approved or in. the alternative, the ordinance may be amended <br />eliminating this requirement. <br />all refuse/recycling storage must be inside ofthe building. <br />the loading dock and. outside mechanical must be screened from the. public <br />right -cif -way the shrubs planned for the Scheuneman side of the road will. <br />provide some buffering of the larger drive-in door. The loading dock. has very <br />limited screening- proposed. Staff. suggested that the two additional frees be <br />placed to help with the dock scree.n1ng:. <br />e No sewer and water is planned to be extended to the building as no restrooms <br />are proposed <br />The City Engineer has. done. a preliminary review of the plan and. offers the following <br />comments:: <br />plans need to be signed bya P.E. <br />