Laserfiche WebLink
4.0 BACKGROUND <br />4.1 The property, located in Planning District 12, has a Comprehensive Plan designation of <br />Low - Density Residential (LR) and a zoning classification of Single - Family Residence <br />(R -1) District. <br />4.2 Applications for typical RECOMBINATIONS only require the approval of the City Council; <br />they do not require public hearings. In situations where more issues are involved, like the <br />VARIANCE that would also be required in this case, the Community Development Director <br />may refer the application to the Planning Commission for its recommendation before the <br />application is brought to City Council for final action. <br />5.0 REVIEW OF PROPOSED RECOMBINATION <br />5.1 The residential parcel addressed as 2045 Loren Road comprises two legal lots of record: <br />Loren Acres No. 1, Lots 3 and 4, Block 1, platted in 1903. Lot 3, where the existing <br />residence is located, is in excess of 50,000 square feet and Lot 4, which is currently <br />undeveloped, is nearly 33,000 square feet. The minimum required area for a residential <br />lot is 11,000 square feet. <br />5.2 The proposed RECOMBINATION would take about 2,000 square feet from Lot 3 near the <br />street and add it to Lot 4, and would take about 2,400 square feet from the back of Lot 4 <br />and append it to Lot 3. This exchange of land would alter the alignment of the common <br />lot line, but would leave the properties essentially the same size as they were platted. <br />5.3 The property boundary common to Lots 3 and 4 is a straight line and is nearly radial to <br />the circular end of the adjacent cul -de -sac street; this is consistent with the requirements <br />of § 1103.00 (Lot Standards) of the City Code. The proposed realignment of the common <br />lot line would make Lot 4 a somewhat more regular, rectangular parcel, but it would not <br />conform to the requirement that side property lines be perpendicular (or, in this case, <br />radial) to the adjacent street. Based on a site visit, Planning Division staff concurs with <br />the statements in the applicant's narrative (included as Attachment D) that the proposed <br />lot configuration would distribute the land area between the two properties in a more <br />reasonable and usable fashion. In order to approve the requested RECOMBINATION a <br />VARIANCE must also be approved. <br />5.4 Aside from the noncompliant alignment of the shared property boundary, all other <br />requirements for lot area and dimensions are met in the proposed RECOMBINATION. <br />6.0 REVIEW OF PROPOSED VARIANCE <br />0.1 Section 1103.06F (Side Lot Lines) of the City Code requires that side lot line to be <br />perpendicular (or radial, if the lot is on a curve) to the adjacent street. Since this property <br />is on the circular end of Loren Road, a cul -de -sac street, the side lot lines are to be radial <br />to the adjacent turn - around, but the proposed configuration of the new lot line does not <br />meet this requirement. <br />0.2 Section 1104.05 of the Code states: "Hardship: Where there are practical difficulties or <br />undue hardships in the way of carrying out the strict letter of the pro visions of this Code, <br />the y <br />C , t Council shall lea ve the power, in a specific case and after notice and pu bllc <br />PF98 -919 RCA 991998.doc <br />Page 2 of 5 <br />