Laserfiche WebLink
4.0B <br />ACKGROUND <br />12 <br />4.1The subject property, located in Planning District 4, has a Comprehensive Plan Land Use <br />13 <br />Designation of Low-Density Residential (LR) and a zoning classification of Low-Density <br />14 <br />Residential-1 (LDR-1) District. The application does not seek to <br />15 PRELIMINARY PLAT <br />change the zoning classification of the property, and so the lot size and residential density <br />16 <br />requirements will remain the same for the proposed subdivision as for the surrounding <br />17 <br />neighborhood. <br />18 <br />4.2When exercising the so-called “quasi-judicial” authority when acting on a request, <br />19 PLAT <br />the role of the City is to determine the facts associated with a particular request and apply <br />20 <br />those facts to the legal standards contained in the ordinance and relevant state law. In <br />21 <br />general, if the facts indicate the applicant meets the relevant legal standard, then they are <br />22 <br />likely entitled to the approval, although the City is able to add conditions to a plat <br />23 <br />approval to ensure that the likely impacts to roads, storm sewers, and other public <br />24 <br />infrastructure on and around the subject property are adequately addressed. <br />25 <br />5.0PPA <br />RELIMINARYLATNALYSIS <br />26 <br />5.1Plat proposals are reviewed primarily for the purpose of ensuring that all proposed lots <br />27 <br />meet the minimum size requirements of the zoning code, that adequate streets and other <br />28 <br />public infrastructure are in place or identified and constructed, and that storm water is <br />29 <br />addressed to prevent problems either on nearby property or within the storm water <br />30 <br />system. <br />31 <br />5.2As a of a residential subdivision, the proposal is subject to the <br />32 PRELIMINARY PLAT <br />minimum lot sizes and roadway design standards of the subdivision code, established in <br />33 <br />Chapter 1103 (Design Standards). The proposed is included with this <br />34 PRELIMINARY PLAT <br />report as Attachment C, and the applicable standards are reviewed below. <br />35 <br />a.City Code §1103.02A (Streets/Right-of-Way) <br />: The proposed cul-de-sac will only <br />36 <br />provide access to the new homes in the plat and will not serve as a through street, <br />37 <br />creating a marginal access street. Also, there is not a need for additional right- of- way <br />38 <br />for underground utilities. As result, Public Works Department staff has recommended <br />39 <br />that the plat dedicate 50 foot wide right-of-way for this marginal access street. <br />40 <br />b.City Code §1103.021C (Minimum Roadway Standards/Cul-de-sacs): <br /> The <br />41 <br />standard design for a cul-de-sac is to have a circular terminus with a pavement diameter <br />42 <br />of 100 feet. The proposed street is approximately 150 feet long. Adding a 100-foot- <br />43 <br />diameter cul-de-sac makes the street 250 feet long. After taking into consideration the <br />44 <br />shortness of the proposed street, the Public Works Director is recommending an <br />45 <br />alternative to this standard design. Instead of the standard 100-foot-diameter cul-de-sac, <br />46 <br />Public Works is recommending an 80-foot-diameter cul-de-sac. The reduced pavement <br />47 <br />area will create a more sustainable design, with less storm water runoff, less snow to <br />48 <br />remove, and eventually less pavement to replace. The alternative design is supported by <br />49 <br />the Fire Department. <br />50 <br />c. <br />Right-of-way for a circular turnaround on a cul-de-sac street is required to have at <br />51 <br />least 10 feet outside of the proposed back of curb on the cul- de- sac. The proposed plat <br />52 <br />dedicates 15 feet outside of the proposed back of curb on the cul- de- sac, for a dedication <br />53 <br />of 110 foot diameter cul- de- sac right- of- way. <br />54 <br />PF13-005_RCA_052013 (2).doc <br />Page 2 of 4 <br /> <br />