My WebLink
|
Help
|
About
|
Sign Out
Home
pf09-002
Roseville
>
Planning Files
>
2009
>
pf09-002
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/29/2014 3:46:44 PM
Creation date
6/21/2013 2:49:37 PM
Metadata
Fields
Template:
Planning Files
Planning Files - Planning File #
09-002
Planning Files - Type
Planned Unit Development
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
431
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
-� --� <br />setback (south), a 10-foot interior side yard setback (north), and a 30-foot rear-yard setback <br />(east). As shown on the Site Plan, the Orchard meets a number of these setback requirements. <br />The DRC has discussed the possibility of vacating a portion of the underutilized right-of-way <br />for Midland Grove Road, which, if vacated, could increase the official front yard setback, but <br />would not change its proximity to the road. <br />6.11 Access/Traffic: The applicant proposes to access the site and building via Midland Grove Road <br />(a public road). Trip Generation engineering data (Institute of Transportation Engineers' Trip <br />Generation Report, 8th Edition (2008) provided by the applicant's consultant indicates that a <br />55-unit senior development could generate approximately 193 trips/day overall or <br />approximately 3.5 trips/day per household. Assuming the same trip generation from the <br />Midland Grove Condominium, the existing 174 units would create 609 trips per day or a total <br />of 802 trips per day for the two developments. <br />6.12 Parkin�: Section 1019.10(A) of the City Code sets minimum parking standards by use. This <br />section does not specifically identify a parking requirement for assisted-living units as a use <br />and, per to Section 1019.10(B), "where land uses are proposed that are not specifically listed <br />above [within 1019.10(A)], the City Council shall establish a reasonable number of off-street <br />parking space for such use." The City Code has established parking requirements for nursing <br />homes and senior housing at one space per four beds and one enclosed space plus 0.3 spaces of <br />visitor parking, respectively. The Planning Division has determined that on-site parking shall <br />be 55 enclosed and 16 surface spaces, or 71 total spaces. Based on the proposal, resident and <br />employee parking will be accommodated through enclosed parking located under the building <br />at 83 planned spaces, and visitor parking accommodated via a parking lot with <br />approximately 19 spaces. <br />6.13 Landscapin� The applicant has indicated a strong desire to preserve as many trees as feasibly <br />possible, especially those near the intersection of County Road B and Midland Grove Road and <br />north along Midland Grove Road. The applicant will also attempt to preserve and/or transplant <br />some of the apple trees that dot the property. As for proposed landscaping, the plan indicates <br />boulevard trees, interior trees and shrubs throughout the site. Shrubs would act as a natural <br />screen for the main level patios and all storm water management areas will require some from <br />of heightened landscape. <br />6.14 Pathways and Sidewalks: Section 1013.07 of the City's Code requires that new non-motorized <br />pathways be constructed as part of new development on properties that are designated through <br />the official pathway system plan. However, the plan does not indicate sidewalk or path <br />requirement along the north side of County Road B. The DRC is recommending a sidewalk <br />from Midland Grove Condominium parcel to County Road B adjacent Midland Grove Road <br />and looking into a way in which sidewalk can be provided from Midland Grove Road to <br />Cleveland Avenue, where the identified crossing lies. <br />6.15 Storm Water: Storm water will be collected and treated on site. The conceptual storm water <br />management plan indicates three infiltration areas, one at the rear of the building to assist with <br />adjacent property drainage, and the other two in the southwest corner of the property. <br />6.16 Sanitarv Sewer and Water: Sanitary sewer and water will be provided by a water main and <br />sanitary sewer connection located within County Road B. <br />6.17 Private Utilities: The private utilities, such as electricity, cable, telephone, and natural gas, will <br />be designed and coordinated through the Public Warks Department to be underground and <br />utilize a joint trenching system, where applicable. <br />PF09-002_RPCA_030409.doc Page 6 of 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.