^ MECHANICAL AND ELECTRICAL REQLIIREMEN"f8 <br />cilities in accordance with the 1CC Electrical Code. Dwelling <br />units shall be served by a three-wire, 120/240 volt, single- <br />phase electrical service having a rating of not less than 60 am- <br />peres. <br />604.3 Electrical system hazards. Where it is found that the <br />electrical system in a struccure constitutes a hazard to the occu- <br />pants or the s�ucture by reason of inadequate service, improper <br />fusing, insufficient receptacle and lighting outlets, improper <br />wiring or installation, deterioration or damaoe, or for similar <br />reasoas, the code official shal] require the defects to be cor- <br />rected to eliminate the hazard. <br />SECTION 605 <br />ELECTRICAL EQUIPMENT <br />605.1 Installation. All electrical equipment, wiring and appli- <br />ances sha11 be properly installed and maintained in a safe and <br />approved manner. <br />605.2 Receptacles. Every habitable space in a dwelling shall <br />contain at least [wo separate and remote receptacle outlets. Ev- <br />ery laundry area shall contain at least one grounded-type recep- <br />C3C!P cr a �ecept2c!e �.vith 3 brOL'.^.� fau,t circuit ;af�TJt.TeI'. <br />Every batbroom shall contain at least one receptacle. Any new <br />bathroom receptacle outlet shall have ground fault circuit inter- <br />rupter protection. <br />--� <br />605.3 Lighting fixtures. Every public hall, interior stairway, <br />toilet room, kitchen, bathr��m,laundry room, boiler room and <br />furnace room shall contain ai.l.°,asi: one electric lighting fixture. <br />�-. <br />SECTION 606 <br />ELEVATORS, ESCALATORS AND DllMBWAITERS <br />606.1 General. Elevators, dumbwaiters and escalators shall be <br />maintained to sustain safely all imposed loads, to operate prop- <br />erly, and to be free from physical and fire bazards. The most <br />current certificate of inspection shall be on display at all times <br />within the elevator or attached to the escalator or dumbwaiter; <br />or the certificate shali be available for public inspection in the <br />o�ce of the building operator. <br />606.2 Elevators. In buildings equipped with passenger eleva- <br />tors, at least one elevator shall be maintained in operation at all <br />times when the building is occupied. <br />Exception: Buildings equipped with only one elevator shall <br />be permitted to have the elevator temporarily ou[ of seivice <br />for testing or servicing. <br />ScCTION 607 <br />DUGT S`(STEMS <br />6Q7.1 General. Duct systems shall be maintained free of ob- <br />stiuctions and shall be capable of performing the required func- <br />tion. <br />18 2Q03 INTERNATIONAL PROPERTY MAINTENANCE CODE� <br />