My WebLink
|
Help
|
About
|
Sign Out
Home
pf_02976
Roseville
>
Planning Files
>
Old Numbering System (pre-2007)
>
PF2000 - PF2999
>
2900
>
pf_02976
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2007 12:26:35 PM
Creation date
12/8/2004 1:55:40 PM
Metadata
Fields
Template:
Planning Files
Planning Files - Planning File #
2976
Planning Files - Type
Planning-Other
Address
2800 ARONA ST
Applicant
ARONA DEVELOPMENT
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
243
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />3.0 RESULTS OF INSPECTION <br /> <br />3.1 Types of ACM Identified <br /> <br />Refer to the INSPECTION RESULTS TABLE for details of the <br />results. <br /> <br />Friable Thermal Insulation <br /> <br />The friable asbestos-containing material identified in the <br />NCR Comten Training Center is thermal systems insulation. <br />The water heater tank insulation and the pipe fittings <br />insulation were found to contain asbestos. A 6 inch pipe, <br />approximately 10 feet long, on the boiler is wra~ped with <br />asbestos-containing insulation. The remaining ~1pe <br />insulation in the building is not asbestos. (F1gure 1) <br /> <br />Nonfriable Floor Tile <br /> <br />The 9" x 9" floor tiles sampled in the training center <br />(Figure 3) were sampled and found to contain asbestos. The <br />floor tiles are a nonfriable material until they are broken <br />up. Isolated areas are damaged and the majority of the tile <br />are very brittle. The mastic was found not to contain <br />asbestos. <br /> <br />The 12" x 12" floor tiles are not asbestos. <br /> <br />Miscellaneous Materials <br /> <br />2' x 4' ceiling tiles were sampled in the Facility (Figure 2) <br />and are not asbestos. <br /> <br />The sheetrock panels and tectum ceiling were sampled and are <br />not asbestos. <br /> <br />3.2 Quantity Summary of ACM Identified <br />The approximate quantities of ACM identified are as follows: <br />- Thermal Systems Insulation = 120 Fittings <br />10 Linear Feet <br /> <br />- Thermal Water Heater Insulation = <br /> <br />210 Square Feet <br /> <br />- Floor Tile (9" x 9") <br /> <br />= 7,500 Square Feet <br /> <br />3.3 Analytical Results <br />Refer to the attached Braun Laboratory Report <br /> <br />lea COHTEN ASBESTOS REPORT <br /> <br />PAGE 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.