My WebLink
|
Help
|
About
|
Sign Out
Home
pf_03154
Roseville
>
Planning Files
>
Old Numbering System (pre-2007)
>
PF3000 - PF3801
>
3100
>
pf_03154
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2007 12:47:21 PM
Creation date
12/8/2004 3:55:03 PM
Metadata
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
315
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br /> <br />DJuj <br /> <br />Memo <br /> <br />2660 Civic Center Drive <br /> <br />Roseville, Minnesota 55113 <br /> <br />(651) 490-2200 <br /> <br />fax: (651) 490-2275 <br /> <br />DATE: <br /> <br />February 22. 2000 <br />Joe Samuel. RLK FA)(l~' ~ '1 33 -\\S~ <br />Debra Bloom, Assistant Public Works Director Qtvb <br /> <br />5"~ \1>~ <br /> <br />TO: <br /> <br />FROM: <br /> <br />CC: <br /> <br />Don Munson <br /> <br />SUBJECT: <br /> <br />Veritas Software building proposal <br /> <br />We have reviewed the revised plans for the Veritas Software Building proposal and we wanted to bring <br />the following items to your attention. We have red-lined the plans to indicate the changes discussed <br />below. <br /> <br />Landscaping Plan: <br />. Care should be taken so that plantings are not over proposed or existing pipes. Upon review of the <br />combined Utility/ Landscape plan, we have observed that there are a number of trees/ shrubs <br />proposed within the proposed easement. No new landscaping should be placed over City utilities. <br /> <br />Overall Grading and Erosion Control: <br />. Erosion Control must be in place before grading is started. <br />. A MN/ Dot right-of-way permit must be acquired for the proposed grading in the 35W right-of- <br />way. <br />. Please provide additional information on the proposed overlook. Please include top of wall and <br />bottom of wall elevations on the grading plan. This should be all along the walls where there are <br />significant elevation changes. <br />. What type of retaining wall is being proposed? If the wall is over 4 feet tall, it should be designed <br />by a professional engineer. <br />. Since the site is larger than 5 acres, it is !lecessary to get a MPCA National Pollutant Discharge <br />Eliminatjon System Permit <br /> <br />Utility construction: <br />. A right-of-way permit is necessary for work with in the Cleveland A venue right-of-way. <br />. Proposed City Storm sewer must be Reinforced Concrete Pipe. <br />. New City lines and connections must be inspected at all times during placement. work should be <br />done per City Specifications and after final inspection. as-builts and a two year maintenance bond <br />are required. These should be provided before a certificate of occupancy being given for the <br />building. <br />. Wet tap is required for the Watermain connection on Cleveland Avenue. <br />. Please contact the Utility Department at least 24 hours before connection to public utilities. (Dan <br />Hansen 651-490-2312) <br />
The URL can be used to link to this page
Your browser does not support the video tag.