Laserfiche WebLink
<br /> <br /> <br /> <br />1.2 Design. Equitable shall and prepare the plans and specifications <br />all of the Transit Hub Improvements using guidelines provided by the RTB and this <br />Agreement. Equitable's design and the plans and specifications for the Transit Hub <br />Improvements, shall be generally consistent with the Site Plan and shall be subject to <br />approval by the R TB, which approval shall not be unreasonably withheld or delayed. The <br />following Transit Hub Improvements shall be designed to the following minimum criteria <br />(which criteria shall control any contrary criteria in the guidelines provided by the RTB): <br /> <br />(a) the Waiting Area shall have 6lnches of class 5 material and a concrete pad of <br />at least 8-inches of non-reinforced concrete; <br /> <br />(b) the Waiting Area Bus Shelter shall be of a material, design and color which is <br />compatible, in the opinion of Equitable, with the other buildings in Rosedale, and <br />shall include a glass-enc 1 osed display case; <br /> <br />(c) the Bus Route shall be constructed or reconstructed of a 2-inch hot-mix wear <br />course, a 4-1/2-inch hot-mix binder course and an II-inch class 5 base; and <br /> <br />(d) the Park and Ride Bus Shelter shall be of a material, design and color which is <br />compatible, in the opinion of Equitable, with the other buildings in Rosedale shall <br />include a glass-encl9sed display case, and otherwise shall be constructed pursuant <br />to the standard bus shelter specifications used by the Metropolitan Transit <br />Commission (the "MTC"). <br /> <br />Equitable shall submit its design, and the plans and specifications, for the Transit Hub <br />Improvements to the R TB for approval when done. If R TB does not disapprove of the <br />design or the plans and specifications, by written notice given to Equitable within 30 <br />business days after submission thereof to the RTB specifying the reasons for the <br />disapproval, then they shall be deemed approved in all respects. If so disapproved by <br />RTB, Equitable shall revise the design, or the plans and specifications, as the case may <br />be, and resubmit them to the RTB for approval and the RTB shall disapprove in writing <br />within the above specified 30 day period or be deemed to have approved the design, and <br />plans and specifications, as the case may be, as submitted. The foregoing process shall be <br />continued until the design, and plans and specifications, are approved or deemed. <br />approved by the R TB. It is understood and agreed that the design shall be first approved, <br />and that the plans and specifications, based on the approved design, shall be subsequently <br />approved, all as above provided. Once the plans and specifications are approved or <br />deemed approved, as above provided, they shall be changed only by wTitten change <br />