My WebLink
|
Help
|
About
|
Sign Out
Home
pf_01704
Roseville
>
Planning Files
>
Old Numbering System (pre-2007)
>
PF1000 - PF1999
>
1700-1799
>
pf_01704
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/28/2016 2:12:12 PM
Creation date
1/27/2016 2:23:26 PM
Metadata
Fields
Template:
Planning Files
Planning Files - Planning File #
1704
Planning Files - Type
Variance
Address
2545 Hamline Ave N
Project Name
Rosepointe
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
146
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� 303.800 Jointi� ,�nd Elec�rical Coc�dugtivitv <br />Bafore laying the pipes, the autside of the spigot and the inside of <br />� the bell shall be wire brushed and wiped clean and dry. �ipe ends <br />ahall be kept clean until joints are made. <br />� <br />All joi.nting of ineeharaical joint pipe and push-on pipe shall be in <br />aeeordance with the requirements of the A.W.W.A. Star�dard C60d. <br />Ductile iron pipe st�all be cut only by sawing, milZing or torch cutting <br />� in aecorc3anee with the manufacturertg �°ecommendations, provided the cut <br />joint is properly ground. <br />� <br />� <br />� <br />� <br />� <br />� <br />� <br />Eaeh joint on duatile iron pipe, valves, hydrants or fit�i,ngs, eith�r <br />"push-onf0 or mechana.cal joint type shall be eleatrically bonc.led witY� an <br />extended peric�d of time to provide integral electric thawing <br />capabilities. <br />These copper jumpers aan be eith�r shop or field applied in accordance • <br />with these specii'ication�. For field appiied copper jumpers, either � <br />the "�urnd��ThermoN�ld", as supplied by Surndy Corporation, Norwalk, <br />Connecticut, or "Caldweld", by Erico Pr�duets Company, Cleveland, Ohio <br />wfll be permitted. <br />Contractors or suppliers shall submit the method they propose to use <br />for approval p.rior to oonstruction. <br />The capper jumper shall be a minimum 1/i6" � 1/2" wide flat <br />strip or equal crogs section round copper wire in the annealed <br />cotidition conforming to A�TM Specifioation B152-58 Type DHP. <br />All copper jumpers shall be welded to the pipe and fittings by the <br />metallic-arc welding process, if shop rpplied or by the exothermic <br />welding process if fi�ld applied. <br />The copper jumper can be applaed as a single strip welded at eaeh end <br />� ac,:�oss the jaint or by multiple strips with bolted connections in the <br />middle. Silicon bronze balts and nuts shall be used on all Uolted <br />connections. <br />� <br />� <br />O <br />� <br />Al1 welded canneetions shall be made on a clean metal surface which has <br />been ground to remove coating and oxide. The area at the connection, <br />including 'the weld, shall be reffnished wit,h its ariginal coating ar <br />other suitable proteetive coatings specified. <br />The asssmbled copper jumper across the jaints shall be so installed <br />that expansion9 contraetion, or relative pipe movement incidental to <br />normal service use will not damage the connection to sueh an Extent <br />that electrical resist�nce will vary across the joint. <br />The completed watermain system shall b� tested for electrical <br />conductivity aecording to that stated ir� tzsting in these <br />specif ications. <br />0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.