703.1 Repair or maintain the required fire-resistance rating of fire-resistance-rated <br />construction (including walls, fire stops, shaft enclosures, smoke barriers, partitions and <br />floors). <br />304.1 Remove outdoor combustible waste material from the property. <br />605.4 Multiplug adapters, such as cube adapters, unfused plug strips or any other device <br />not complying with the ICC Electrical Code shall be prohibited. <br />605.3.1 Doars into electrical control panel rooms shall be marked with a plainly visible <br />and legible sign stating ELECTRICAL ROOM or similar approved warding. The <br />disconnecting means far each service, feeder or branch circuit originating on a <br />switchboard or panelboard shall be legibly and durably marked to indicate its purpose <br />unless such purpose is clearly evident. <br />1028.3 All portions of the means of egress shall be maintained free from obstructions <br />that would prevent their use including the accumulation of snow and ice. <br />605.1 Repair or replace damaged or missing electrical fixtures. <br />703.2.3 Repair or replace the required fire-rated doars so they fully close and latch when <br />activated by their closing device. <br />605.1 Repair or replace damaged or exposed electrical wiring. <br />3403.5 Label all containers with product specific identification. <br />3404.3.2.1.2 Provide 'DANGER- KEEP 'FIRE AWAY' or 'DANGER- FLAMMABLE <br />LIQUIDS-NO SMOKING' 'FLAMMABLE - KEEP FIRE AWAY' sign on door of all <br />flammable liquid storage cabinets. <br />603.5.2 Provide written documentation from a licensed heating contractor that the heating <br />appliances are installed and being maintained in accordance with the manufacturer's <br />instructions, the State Building Code, and the State Mechanical Code. <br />903.6 The provisions of this section are intended to provide a reasonable degree of <br />safety in existing structures not complying with the minimum requirements of the <br />International Building Code by requiring installation of an automatic fire-extinguishing <br />system. <br />1004.3 Every room or space that is an assembly occupancy shall have the occupant load <br />of the room or space posted in a conspicuous place, near the main exit or exit access <br />doorway from the room or space. Posted signs shall be of an approved legible permanent <br />design and shall be maintained by the owner or authorized agent. <br />703.1 Repair or seal openings or penetrations to fire-resistive construction with <br />approved materials and methods. <br />508.5.4 Provide and maintain unobstructed access to all fire sprinkler valves. <br />703.1 The required fire-resistance rating of fire-resistance-rated construction (including <br />walls, firestops, shaft enclosures, partitions, smoke barriers, floors, fire-resistive coatings <br />and sprayed fire-resistant materials applied to structural members and fire-resistant joint <br />systems) shall be maintained. Such elements shall be properly repaired, restored or <br />replaced when damaged, altered, breached or penetrated. Openings made therein for the <br />