Resolution #
11349
Resolution Title
Approving Abatement Action at 2814 Cleveland Avenue North
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
1027.7 Provide approved panic hardware ar fire exit hardware. <br />304.1 Remove outdoor combustible waste material from the property. <br />705.3 Separate incidental use areas from the rest of the building with fire-resistance <br />rated construction where required. <br />315.2.2 Remove and discontinue the storage of combustible materials in exits and exit <br />enclosures. <br />906.2 Provide the required maintenance of the fire extinguishers as required by NFPA <br />10. <br />315.2.3. 2 Arrange the storage of combustible materials in mechanical equipment rooms <br />to comply with the following: <br />1) all storage to be neat and arderly, 2) no storage within 3 feet of fuel-fired equipment <br />1001.2 It shall be unlawful to alter a building or structure in a manner that will reduce <br />the number of exits or the capacity of the means of egress to less than required by this <br />code. <br />1028.3 All portions of the means of egress shall be maintained free from obstructions <br />that would prevent their use including the accumulation of snow and ice. <br />907.20.5 The building owner shall be responsible for ensuring that the fire and life safety <br />systems are maintained in an operable condition at all times. Service personnel shall meet <br />the qualification requirements of NFPA 72 for maintaining, inspecting and testing such <br />systems. A written record shall be maintained and shall be made available to the fire code <br />official. <br />304.3.3 Relocate dumpster at least 5 feet away from combustible walls, openings, or <br />combustible eaves and overhangs. <br />903.3.1.1 Where the provisions of this code require that a building or portion thereof be <br />equipped throughout with an automatic sprinkler system in accordance with this section, <br />sprinklers shall be installed throughout in accordance with NFPA 13 except as provided <br />in Section 903.3.1.1.1. <br />503.4 Ensure that fire lanes and fire apparatus access roads are maintained free of <br />obstructions, and that the required minimum widths and clearances are maintained at all <br />times. <br />3404.2.3.1 Provide approved signs prohibiting open flames and smoking within <br />flammable/combustible liquid storage areas. <br />603.5.3 Provide the proper clearances between heat-producing appliances and <br />combustibles. Where specific manufacturer's instructions or listings allow a reduction <br />from the distances specified in Sections 603.5.3.2, those distances are allowed. <br />3404.3.43 Provide a flammable liquid storage room constructed and separated in <br />accordance with the MN State Fire Code. <br />603.9 Provide approved impact protection for gas meters, regulators and piping subject <br />to physical damage. <br />