Laserfiche WebLink
Figure 1012-7: Deck Encroachment 525 <br />vi. Additional structure setbacks: Structures must also meet the following setbacks, 526 <br />regardless of the waterbody classification. 527 <br />A. 30 feet from the top of the bluff 528 <br />B. 50 feet from an unplatted cemetery 529 <br />vii. Bluff Impact Zones: Structures, impervious surfaces, and accessory facilities, except 530 <br />stairways and landings, must not be placed within bluff impact zones. 531 <br />b. Height of Structures: All structures must meet the height limitations of the underlying zoning 532 <br />district. 533 <br />c. Lowest Floor Elevation 534 <br />i. Determining elevations: Structures must be placed at an elevation consistent with the 535 <br />applicable floodplain regulatory elevations. Where these controls do not exist, the 536 <br />elevation to which the lowest floor, including basement, is placed or flood-proofed must 537 <br />be determined for lakes by placing the lowest floor at a level at least three feet above the 538 <br />highest known water level, or three feet above the ordinary high water level, whichever is 539 <br />higher (see Figure 1012-8). 540 <br />RCA Attachment A <br />Page 19 of 32