My WebLink
|
Help
|
About
|
Sign Out
Home
ord_163
Roseville
>
City Council
>
City Council Ordinances
>
0100
>
ord_163
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2007 9:03:49 AM
Creation date
4/22/2005 12:49:41 PM
Metadata
Fields
Template:
Roseville City Council
Document Type
Council Ordinances
Ordinance #
163
Ordinance Title
An ordinance relating to the installation, alteration, repair or service to gas burners, gas burner equipment and to portable or domestic incinerators installed in connection with gas space heating devices and vented into the same chimney flu; estab
Ordinance Date Passed
8/18/1953
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />ORDINANCE No. 163 <br /> <br />14:.i <br /> <br />SECTION 2-25.2 <br /> <br />Luminous flame pilots shall not show carbon deposits when adjusted <br />according to the manufacturers' instructions. <br /> <br />SECTION 2 - 25.3 <br /> <br />Where escapement pilots are used, their f~ames shall be freely ignited <br />by the constant burning pilot. <br /> <br />SECTION 2 - 26 BURNER OPERATION: <br /> <br />. <br />The flames from each burner shall freely ignite the gas from adjacent <br />burners when operating at the normal gas pressure or when th,e main control <br />valve is regulated to deliver about one-third (1/3) the full gas rate, except <br />where additional pilots are provided. If the additional pilot is a runner <br />type pilot, this pilot must be proven by a safety mechanism before the main <br />burner valve can open. <br /> <br />SECTION 2 - 26.1 <br /> <br />Burner flames shall not flash back upon immediate ignition, nor upon <br />turning the gas cock until the gas rate to the burner is about one-third 0/3) <br />the full supply. <br /> <br />SECTION 2 - 26.2 <br /> <br />Burner flames shall not flash back when the gas is turned on or off by <br />any automatic control mechanism. <br /> <br />SECTION 2 - 26.3 <br /> <br />. <br />Main burner flames shall ignite freely from each constant burning pilot <br />when the main control valve is regulated to deliver about one-third (1/3) <br />the full gas rate and when pilot flame is reduced to minimum point at which it <br />will actuate the safety thermostatic device. The holding port of multiple <br />port pilots must satisfactorily ignite the main burner if the ignition port, <br />or port~, are stopped. <br /> <br />SECTION 2 - 26.4 <br /> <br />Burners shall be of such design that ignition from pilot or pilots <br />will carry to all p.rts or burner heads protected by the pilot at inputs from <br />one-third (1/3) to Maximum rating. <br /> <br />SECTION 2 - 26.5 <br /> <br />. <br />When ignition is made in a normal manner, the names shall not flash <br />outside the appliance. <br /> <br />SECTION 2 - 26.6 <br /> <br />Burners shall not expel gas through air openings in mixer faces when <br />operating at the normal burner pressure. . <br />Note: In making the test under Sections 2-25 and 2-26, c~ shall be exercised <br />to prevent the accumulation of unburned gas in the appliance o.r flues which <br />might result in explosion or fire.. <br />
The URL can be used to link to this page
Your browser does not support the video tag.