Laserfiche WebLink
<br />14-1 <br /> <br />SECTION 2 - 17 ELECTRIC WIRING: <br /> <br />All electrical connections shall be made in accordance with the provisions <br />of all Building and Electrical codes relating to the installation of electric <br />wiring in the Village of Rosevil1e. <br /> <br />SECTION 2 - 18 GAS PRESSl~ REGULATORS: <br /> <br />A gas 'pressure regulator, approved by the Gas Inspector, shall be installed <br />on the down-stream side of the pilot supply on all gas burners, and a pressure <br />regulator and pilot filter shall be installed in all pilot lines, downstream <br />from the pi10t shut-off cock, on all burners. Pressure regulators and pilot <br />filters shall be of types listed for approval by the American Gas Association and <br />shall be apprc'Ved by the Gas Inspector. . . <br /> <br />SECTION 2 - 19 LIMITING DEVICES: <br />, <br /> <br />The boiler or furnace shall be equipped with safety devtces arranged to <br />li.mit high steam pressures or water temperatures, as well as high air tempera- <br />tures in warm air furnaces, and all such devices shall be subj ect to the approval <br />of the Gas Inspector. <br /> <br />SECTION 2 - 19.1 <br /> <br />Each gas fired steam boiler shall be equipped with a low-water cut-off, <br />approved by the Gas Inspector. <br /> <br />SECTION 2 - 19.2 <br /> <br />Safety devices operated electrically shall not depend upon the closing <br />of a circuit to shut off the'main gas supply. Thi! requirement shall not be <br />construed as prohibiting the use of electrical regulating devices, provided <br />the required safety devices are also installed. Controls shall be so connected <br />that maximum inherent safety provided by such controls will be attained. <br /> <br />SECTION 2 - 20 SAFETY SHUT-OFF VALVES: <br /> <br />Safety shut-off valves if used shall be tested to assure gas tightness of <br />the seat when in the closed position; the valve assembly shall be gas tight in <br />all positions. Packing glands shall be designed so tha.t the valve will not be <br />made inoperative by excessive tightening of the packing nut. <br />Either the valve shall incorporate means for requiring manual operation <br />for re-opening of the valve after it has closed or the electrical circuit <br />shall be so arranged as to require' a manual operation to re-open the valve <br />after it has been closed. In no case shall valve5 be able to be opened manually <br />until safety pilots are lighted and circuit completed or low-water cut-off circuit <br />has been completed. . <br /> <br />SECTION 2 - 21 PIPING: <br /> <br />Gas piping installed for se!ving conversion burners or gas designed heating <br />appliances shall be sized for a total pressure drop not exceeding 0.3 inches <br />water gauge from the meter to the burner for the total connected load. 'A <br />separate pipe from the meter is to be preferred and in no case shall the service <br />pipe be smaller than the size of equipment connection. All gas piping shall be <br />installed in conformance with the provisions of this Ordinance. <br />