My WebLink
|
Help
|
About
|
Sign Out
Home
ord_190
Roseville
>
City Council
>
City Council Ordinances
>
0100
>
ord_190
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2007 9:03:52 AM
Creation date
4/22/2005 12:50:05 PM
Metadata
Fields
Template:
Roseville City Council
Document Type
Council Ordinances
Ordinance #
190
Ordinance Title
Building Code. An ordinance regulating all matters pertaining, relating or incidental to and the construction, building, alteration, repair, installation, performance, maintenance and inspection of all buildings, walks, structures, driveways, signs
Ordinance Date Passed
7/20/1954
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
66
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />U <br />/..1 'J tI <br /> <br />6-4$A All that part of any chimney above the roof line shall be constructed <br />with pressed brick mater:Laj.. This shall be required regardless or the <br />type of chimney used inside the building or the particular purpose of <br />the chimney, except chimneys described in 6-46 <br /> <br />6-46 Fabricated chirrmeys, designed for particular types and methods of <br />heating ?nd meeting or exceeding the runctional requirements speciri- <br />cally mentioned in this code, may be approved by the governing body <br />of the municipality. All such chimneys and material shall be app- <br />roved by the National Board or Fire Underwriters. These chimneys, <br />whcn used shall not require brick tops as speciried in 6-45A. <br /> <br />6-41 No smoke pipe shall be placed within twelve (12) inches or any woodwork <br />or wooden lath or plaster partition or ceiling unless the surface above <br />the plaster be protected by metal lath and plaster of any approved fire <br />resistent material. <br /> <br />6-48 Where smoke pipes pass through a wooden alth and plaster partition, they <br />shall be guarded by galvanized iron ventilated thimbles at least twelve, <br />(12) inches larger in diameter than the pipes or by galvanized iron thim- <br />bles built in at least eight (8) inches of brick work or other incom- <br />bustible material. <br /> <br />6-49 No smoke pipe shall pass through any floor or roor having wooden frame- <br />work or.covering. <br /> <br />6-50 The use of a smoke pipe rather than a chimney shall be prohibited. <br /> <br />6-51 No wooden beams, joists or rarters shall be placed within two (2) <br />inches or the outside face of a chimney whether it be for smoke, air .r.....Im~8t <br />or any other purpose. <br /> <br />6-52 The back and sides of fireplaces herearter erected shall bw of solid <br />masonry or reinforoedcconcrete, not less than eight (8) inches in thick- <br />ness. A lining of fire bfick at least tw (2) inches thick or other' <br />approved material shall be provided unless the thiclmess is twelve inches. <br /> <br />, <br />6-53 Fireplaces shall have hearths of brick, stone, tile or other approved <br />non-combustible material supported on a rireproor slab or on brick <br />trimmer arches. Such hearths shall extend at least,sixteen (16) inches <br />outside of the chimney breast and not less than twelve (12) inches be- <br />yond each side of the fireplace opening along the chimney breast. The <br />combined thiclmess or hearth and supporting construction shall be not less <br />than six (6) inches at any point. <br /> <br />6-54 Wooden forms or centers used in the construction of that part of the <br />supporting construction which is below the hearth or the fireplace shall <br />be removed when the supporting construction or the hearth is conpleted. <br /> <br />b-55 No heater shall be placed in a fireplace which does not conform to the <br />requirements of this section or is not provided with a fiue, except <br />electric or gas heaters of a type specifically approved for such installa- <br />tion. <br /> <br />6-56 Ends of all wood joists and girders imbedded in masonry walls shall be <br />fire cut. <br /> <br />-30- <br />
The URL can be used to link to this page
Your browser does not support the video tag.