My WebLink
|
Help
|
About
|
Sign Out
Home
ord_190
Roseville
>
City Council
>
City Council Ordinances
>
0100
>
ord_190
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2007 9:03:52 AM
Creation date
4/22/2005 12:50:05 PM
Metadata
Fields
Template:
Roseville City Council
Document Type
Council Ordinances
Ordinance #
190
Ordinance Title
Building Code. An ordinance regulating all matters pertaining, relating or incidental to and the construction, building, alteration, repair, installation, performance, maintenance and inspection of all buildings, walks, structures, driveways, signs
Ordinance Date Passed
7/20/1954
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
66
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />250 <br /> <br />6-19, Luminous.flame pilots shall not show carbon deposits when adjusted aeco!'ding <br />to the manufacturer's instructions. <br /> <br />6-196 Where escapement pilots are used, their flames shall be f~ely ignited by the <br />constant burning pilot. <br /> <br />6-l96A The flames from each burner shall freely ignite the gas from adjacent burners <br />when operating at the normal gas pressure or when the main control valve is <br />regulated to deliver about oDe-third (1/3) the full gas rate, except where <br />additional pilots are provided. If the additional pilot is a runner type <br />pilot, this pilot must be proven by a safety mechanism before the main burner <br />valve- can open. <br /> <br />f{6,.191 Burner flames shall not flash back upon immediate ignition, nor upon turning <br />the gas cock until the gas rate to the burner is about one third (1/3) the <br />full supply. <br /> <br />6-198 -Burner flames shall not fiash back when the gas is turned on or off by any <br />automatic control meohanism. <br /> <br />6-199 <br /> <br />6-200 <br /> <br />Main bumer .flames shall ignite freely from each eonstant pilot when the <br />main control valve is regulated to deliver about one-third (1/3) the full <br />gas rate and when pilot flame is reduced to minimum point at which it will <br />actuate the safety 'tiMnlostatic device. The Wolding port of multiple port <br />pilots must satisfactorily ignite the ~ burner if the :ignition port, <br />are stopped. <br /> <br />Burners shall be of such design that ignition from pilot:3or pnots will <br />carry to all 'ports or burner heads protected QY the pilot at inputs from <br />one-third (1/3) to maximum rating. <br />When ignition is made in a nonu4 manner, the flames shall not flash outsid e <br />the appliance. <br />Burners shall not ~l gas through air openings in mixer faces when oper- <br />ating at the normal bUrner pressure. <br />Note: In maldng the test under 6-193 and 6-196, care shall be exelrcised to <br />prevent the acc\lJlU1ation 01' unburned ias in the appliance or flues which <br />might result in explosion or fire. <br /> <br />The fiue gas temperature as taken on the appliance side 01' the draft hood <br />shall not exceed 4800F. above '\;hat 01' the air temperature surrounding the <br />appliance. The c mcentration of CO2 shall not exceed 9%, the concentration <br />01' CO shall not exceed .04%, the co-.ntJation 01' exygen shall not be less <br />than ,% not more than 10%. , <br /> <br />6-202 The rate 01' flow of the gas shall be adjusted to wi thin plus or minus two (2) <br />percent 01' the required hourly BTtJ input rating at the mani.told pressure <br />. specified by the manufacturer. When the prevailing pressure is less ~an <br />the manifold pressure specified, the gas rate shall be adjusted at the <br />prevailing pressure. The appliance shall be allowed to operate until the <br />stack temperature becomes stabilieed, after which a sample of the flue <br />products shallU.. taken at a point in the flue after the outlet of the <br />appliance but ahead of the draft hood, and analyzed for carbon dioxide, <br />carbon monoxide and oxygen <br /> <br />6-201 <br /> <br />6-203 The rate of flow of gas shall be adjusted to wi thin plus ,% or minus 1,% of <br /> <br />-41- <br />