<br />251 <br /> <br />1.7 times the calculated hO'lrly BTU heat loss of the building in which it is <br />installed. The appliance shall Qe allowed to operate until the stack <br />temperature becomes stabilized, after which a sample of the flue prod- <br />ucts shall be taken at a point in the flue after the outlet of Im.e <br />appliance but ahead of the draft hood, and analyzed for carbon diOXide, <br />carbon monoxide and oxygen. <br /> <br />6-204 The various controls of the appliance shall be checked by both in- <br />spector and installer, to insure the'iT proper operation. <br />Upon completion of the test of any nswly installed gas burning equip.. <br />ment as hereinafter provided in 6-201, the installer shall file with the <br />Heating Inspector, in duplicate complete records of .such test. <br /> <br />6-205 The owner and / or occupant shall be thoroughly instructed by the in- <br />staller as to the proper and safe operation of the appliance before it <br />is placed in sernce, such instructions to include actl.\8l demonstration <br />to the customer or his authorized agent of the process.ss of lighting <br />and turning off the gas burner. A printed set of instructions, en- <br />closed in an envelope labeled "Instructions to Customer, It shall bj <br />securely attached to the gas valve. <br /> <br />6-206 A metallic plate" suitable etched or stamped" setting fort.h detailed t <br />instructions for. the safe lighting and shutting off of the appliance, <br />shall be permanently attached to the appliance in a prominent position <br />near the lighting apert.ures. The size and type used shall be not <br />smaller than ten (10) point and the wording contained "hereon shall be <br />subject to the approval of the Heating Inspector. This plate shall "J~ <br />also state make and model numbers of the burner and show the rate <br />hourly gas BTU input. <br /> <br />EXGEEDING 400,000 BTU PER HOUR <br /> <br />6-207 The construction arrangement, manner of inatlllation, alteration and <br />repair of all gas burners in siseam and hot water boilers, furnaces and <br />air heaters having an input capacity exceeding 400,000 BTU per hour, <br />and for power, industrial and process uses shall conform to the follow- <br />ing provisions of this dode. The 'requirelll8nts for installation of gas <br />burning equipment in power boilers as adopted by the Ameriean Standards <br />Association, sponsered by the American Gas Association, shall be consid- <br />ered herein as minimum re qui reJllen ts. <br /> <br />6-208 All burners shall be accOlIlpanied by complete and comprehensive in- <br />stallation and operating instructions. <br /> <br />6-209 Where burners are equipped with secondary air shutters or louvres, they <br />must be so designed or counter-balanced. so as to drop to a wide open <br />posi tion in the event of failure or 'breakage of connecting liilkage. They <br />shall also bj of sufficient area to supply adequate air for complete <br />combustion under specified draft conditmons and. at the maximum rate <br />of firing. <br /> <br />6-210 The air intake on power burners must be protected wi th means to preveIi,j <br />accidental closure by debris being pulled over inlet by suction of blower. <br /> <br />6-211 The burner or burners shall be located according to the manufacturers' - <br />instructions and shall be so secured that they will not slide, twist <br />or drop out of position. <br /> <br />-48- <br />